Abstract:
An investigation of magnetic core losses of an electrodeless fluorescent lamp is presented in this paper. These losses can be divided into two different kinds: static, wh...Show MoreMetadata
Abstract:
An investigation of magnetic core losses of an electrodeless fluorescent lamp is presented in this paper. These losses can be divided into two different kinds: static, which is related to hysteresis effects, and dynamical, associated to parasitic effects. Experimental results (at 25° C) demonstrate that the total losses, in nominal condition point, are approximately 3.18 W, what represent 3.18% of the power supplied to the lamp. In this same point, the static losses are approximately 1.31 W and the dynamic losses about 1.87 W. Based on this, the static losses represent about 41% of total loss related to the magnetic core while dynamical losses represents 59% of total loss.
Published in: 2013 IEEE Industry Applications Society Annual Meeting
Date of Conference: 06-11 October 2013
Date Added to IEEE Xplore: 12 December 2013
ISBN Information:
Print ISSN: 0197-2618