Abstract:

An investigation of magnetic core losses of an electrodeless fluorescent lamp is presented in this paper. These losses can be divided into two different kinds: static, wh...Show More

Abstract:

An investigation of magnetic core losses of an electrodeless fluorescent lamp is presented in this paper. These losses can be divided into two different kinds: static, which is related to hysteresis effects, and dynamical, associated to parasitic effects. Experimental results (at 25° C) demonstrate that the total losses, in nominal condition point, are approximately 3.18 W, what represent 3.18% of the power supplied to the lamp. In this same point, the static losses are approximately 1.31 W and the dynamic losses about 1.87 W. Based on this, the static losses represent about 41% of total loss related to the magnetic core while dynamical losses represents 59% of total loss.