The light-weight thermal-RGB-inertial sensing units are now gaining increasing research attention, due to their heterogeneous and complementary properties. A robust and a...Show MoreMetadata
Abstract:
The light-weight thermal-RGB-inertial sensing units are now gaining increasing research attention, due to their heterogeneous and complementary properties. A robust and accurate registration between a thermal-RGB camera and an inertial sensor is a necessity for effective thermal-RGB-inertial fusion, which is an indispensable procedure for reliable tracking and mapping tasks. This paper presents an accurate calibration method to geometrically correlate the spatial relationships between an RGB camera, a thermal camera and an inertial measurement unit (IMU). The calibration proceeds within the unified calibration framework (thermal-to-RGB, RGB-to-IMU). The extrinsic parameters are estimated by jointly optimizing both the chessboard corner reprojection errors and acceleration and angular velocity error terms. Extensive evaluations have been performed on the collected thermal-RGB-inertial measurements. In this experiments study, the average RMS translation and Euler angle errors are less than 6 mm and 0.04 rad respectively under 20% artificial noise.
Date of Conference: 20-24 August 2018
Date Added to IEEE Xplore: 29 November 2018
ISBN Information:
Print on Demand(PoD) ISSN: 1051-4651