Abstract:
To build a redundant medium-voltage converter, the semiconductors must be able to turn OFF different short circuits. The most challenging one is a hard turn OFF of a diod...Show MoreMetadata
Abstract:
To build a redundant medium-voltage converter, the semiconductors must be able to turn OFF different short circuits. The most challenging one is a hard turn OFF of a diode which is called short-circuit type IV. Without any protection measures this short circuit destroys the high-voltage diode. Therefore, a novel three-level converter with an increased short-circuit inductance is used. In this paper several short-circuit measurements on a 6.5 kV diode are presented which explain the effect of the protection measures. Moreover, the limits of the protection scheme are presented.
Date of Conference: 23-26 October 2016
Date Added to IEEE Xplore: 22 December 2016
ISBN Information: