Multi-Frame CT-Video Registration for 3D Airway-Wall Analysis | IEEE Conference Publication | IEEE Xplore

Multi-Frame CT-Video Registration for 3D Airway-Wall Analysis


Abstract:

Bronchoscopy and three-dimensional (3D) computed tomography (CT) are important complementary tools for managing lung diseases. Endobronchial video captured during broncho...Show More

Abstract:

Bronchoscopy and three-dimensional (3D) computed tomography (CT) are important complementary tools for managing lung diseases. Endobronchial video captured during bronchoscopy gives live views of the airway-tree interior with vivid detail of the airway mucosal surfaces, while the 3D CT images give considerable anatomical detail. Unfortunately, little effort has been made to link these rich data sources. This paper describes a rapid interactive multi-frame method for registering the video frames constituting a complete bronchoscopic video sequence onto their respective locations within the CT-based 3D airway tree. Registration results using both phantom and human cases show our method's efficacy compared to ground-truth data, with a maximum position error = 8.5mm, orientation error of 17°, and a minimum trajectory accuracy = 94.1%. We also apply our method to multimodal 3D airway-wall analysis within a comprehensive bronchoscopic video analysis system.
Date of Conference: 03-07 April 2020
Date Added to IEEE Xplore: 22 May 2020
ISBN Information:

ISSN Information:

Conference Location: Iowa City, IA, USA

Contact IEEE to Subscribe

References

References is not available for this document.