Abstract:
This paper presents a new method named Sampled, Data and Space Vector Technique (SDSV) to control the three-phase, voltages subjected to load changes. The proposed SDSV, ...Show MoreMetadata
Abstract:
This paper presents a new method named Sampled, Data and Space Vector Technique (SDSV) to control the three-phase, voltages subjected to load changes. The proposed SDSV, uses the on record and measured three-phase voltages to obtain, the reference space vector (SVr) and measured one (SVm), respectively at different samples. The two space vectors SVr and, SVm are compared at regular samples of the system sinusoidal, cycle, to generate an error. This error is employed to produce the, new reactive power of compensator in a small period of time, rather than waiting for a complete system sinusoidal cycle, thereby allowing a quick and an efficient Volt-Ampere Reactive, (VAR) control for the three-phase load voltages.
Date of Conference: 21-24 March 2016
Date Added to IEEE Xplore: 19 May 2016
ISBN Information: