Short-Circuit Detection by Means of Empirical Mode Decomposition and Wigner–Ville Distribution for PMSM Running Under Dynamic Condition | IEEE Journals & Magazine | IEEE Xplore

Short-Circuit Detection by Means of Empirical Mode Decomposition and Wigner–Ville Distribution for PMSM Running Under Dynamic Condition


Abstract:

This paper presents and analyzes a method for short-circuit fault detection in a permanent-magnet synchronous motor (PMSM). The study includes steady-state condition and ...Show More

Abstract:

This paper presents and analyzes a method for short-circuit fault detection in a permanent-magnet synchronous motor (PMSM). The study includes steady-state condition and speed transients in motor operation. The stator current is decomposed by empirical mode decomposition (EMD), which generates a set of intrinsic mode functions (IMFs). Quadratic time-frequency (TF) distributions such as smoothed pseudo-Wigner-Ville and Zhao-Atlas-Marks are applied on the more significant IMFs for fault detection. Simulations and experimental laboratory tests validate the algorithms and demonstrate that this kind of TF analysis can be applied to detect and identify short-circuit failures in PMSM.
Published in: IEEE Transactions on Industrial Electronics ( Volume: 56, Issue: 11, November 2009)
Page(s): 4534 - 4547
Date of Publication: 09 January 2009

ISSN Information:


Contact IEEE to Subscribe

References

References is not available for this document.