Abstract:

With the standstill frequency-response (SSFR) test, accurate electrical-machine models can be identified. However, it can be a time-consuming method, particularly in case...Show More

Abstract:

With the standstill frequency-response (SSFR) test, accurate electrical-machine models can be identified. However, it can be a time-consuming method, particularly in case the machine has to be identified at low frequencies. To shorten the required time for identification, in this paper, the response on a broadband signal is measured, resulting in a multisine SSFR test. To generate the broadband signal, a high-power linear amplifier can be applied as a waveform generator. As this signal generator is not commonly available in the field, the application of a voltage-source inverter (VSI) is discussed. The multisine SSFR test with a VSI allows swift evaluation of the influence of frequency, saturation, and cross saturation on the q-and d-axis parameters with a signal generator that is often already available to control the machine. Extensive measurements are performed on several permanent-magnet synchronous machines and the method can be extended to synchronous machines with rotor-field winding. By applying a switching converter instead of a linear amplifier, it can be expected that the identification results are affected by the switching actions. Therefore, multisine SSFR tests with either a VSI or a high-power linear amplifier as well as conventional tests as described in the IEEE standard are performed, and the results are compared.
Published in: IEEE Transactions on Industrial Electronics ( Volume: 57, Issue: 1, January 2010)
Page(s): 430 - 439
Date of Publication: 01 September 2009

ISSN Information:


Contact IEEE to Subscribe

References

References is not available for this document.