Loading [a11y]/accessibility-menu.js
Time-Reversion Fast-Sampling Score-Based Model for Limited-Angle CT Reconstruction | IEEE Journals & Magazine | IEEE Xplore

Time-Reversion Fast-Sampling Score-Based Model for Limited-Angle CT Reconstruction


Abstract:

The score-based generative model (SGM) has received significant attention in the field of medical imaging, particularly in the context of limited-angle computed tomograph...Show More

Abstract:

The score-based generative model (SGM) has received significant attention in the field of medical imaging, particularly in the context of limited-angle computed tomography (LACT). Traditional SGM approaches achieved robust reconstruction performance by incorporating a substantial number of sampling steps during the inference phase. However, these established SGM-based methods require large computational cost to reconstruct one case. The main challenge lies in achieving high-quality images with rapid sampling while preserving sharp edges and small features. In this study, we propose an innovative rapid-sampling strategy for SGM, which we have aptly named the time-reversion fast-sampling (TIFA) score-based model for LACT reconstruction. The entire sampling procedure adheres steadfastly to the principles of robust optimization theory and is firmly grounded in a comprehensive mathematical model. TIFA’s rapid-sampling mechanism comprises several essential components, including jump sampling, time-reversion with re-sampling, and compressed sampling. In the initial jump sampling stage, multiple sampling steps are bypassed to expedite the attainment of preliminary results. Subsequently, during the time-reversion process, the initial results undergo controlled corruption by introducing small-scale noise. The re-sampling process then diligently refines the initially corrupted results. Finally, compressed sampling fine-tunes the refinement outcomes by imposing regularization term. Quantitative and qualitative assessments conducted on numerical simulations, real physical phantom, and clinical cardiac datasets, unequivocally demonstrate that TIFA method (using 200 steps) outperforms other state-of-the-art methods (using 2000 steps) from available [0°, 90°] and [0°, 60°]. Furthermore, experimental results underscore that our TIFA method continues to reconstruct high-quality images even with 10 steps. Our code at https://github.com/tianzhijiaoziA/TIFADiffusion.
Published in: IEEE Transactions on Medical Imaging ( Volume: 43, Issue: 10, October 2024)
Page(s): 3449 - 3460
Date of Publication: 24 June 2024

ISSN Information:

PubMed ID: 38913528

Funding Agency:


Contact IEEE to Subscribe

References

References is not available for this document.