Paper
29 March 2013 Quantification of relative chromatin content in flow cytometry standards using 3D OPTM imaging technique
Author Affiliations +
Proceedings Volume 8676, Medical Imaging 2013: Digital Pathology; 86760T (2013) https://doi.org/10.1117/12.2007281
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
A potential biomarker for early diagnosis of cancer is assessment of high nuclear DNA content. Conventional hematoxylin staining is neither stoichiometric nor reproducible. Although feulgen stain is stoichiometric, it is time consuming and destroys nuclear morphology. We used acidic thionin stain, which can be stoichiometric and also preserve the nuclear morphology used in conventional cytology. Fifty chicken erythrocyte nuclei singlets (CENs), diploid trout erythrocyte nuclei (TENs) and Triploid TENs were stained for 15 and 30 minutes each. After imaging with optical projection tomography microscope (OPTM), 3D reconstructions of the nuclei were processed to calculate chromatin content. The mean of ratios of individual observations was compared with standard ratios of DNA indices of the flow cytometry standards. Mean error, standard deviation and 97% confidence interval (CI) was computed for the ratios of these standards. At 15 and 30 minutes, the ratio of Triploid TEN to TEN was 1.72 and 1.76, TEN to CEN was 1.27 and 2.01 and Triploid TEN to CEN was 2.11 and 3.39 respectively. Estimates of DNA indices for all 3 types of nuclei had less mean error at 30 minutes of staining; Triploid TEN to TEN 0.349±0.04, TEN to CEN 0.36±0.04 and Triploid TEN to CEN 0.64 ± 0.07. In conclusion, imaging of cells with thionin staining at 30 minutes and 3D reconstruction provides quantitative assessment of cell chromatin content. The addition of this quantitative feature of aneuploidy is expected to add greater accuracy to a classifier for early diagnosis of cancer based on 3D cytological imaging.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Nitin Agarwal, Alberto M. Biancardi, Florence W. Patten, Anthony P. Reeves, and Eric J. Seibel "Quantification of relative chromatin content in flow cytometry standards using 3D OPTM imaging technique", Proc. SPIE 8676, Medical Imaging 2013: Digital Pathology, 86760T (29 March 2013); https://doi.org/10.1117/12.2007281
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image segmentation

3D image processing

Cancer

Flow cytometry

3D image reconstruction

Stereoscopy

3D modeling

Back to Top