20 March 2015 Semi-automated measurements of heart-to-mediastinum ratio on 123I-MIBG myocardial scintigrams by using image fusion method with chest X-ray images
Ryosuke Kawai, Takeshi Hara, Tetsuro Katafuchi, Tadahiko Ishihara , Xiangrong Zhou, Chisako Muramatsu, Yoshiteru Abe, Hiroshi Fujita
Author Affiliations +
Abstract
MIBG (iodine-123-meta-iodobenzylguanidine) is a radioactive medicine that is used to help diagnose not only myocardial diseases but also Parkinson’s diseases (PD) and dementia with Lewy Bodies (DLB). The difficulty of the segmentation around the myocardium often reduces the consistency of measurement results. One of the most common measurement methods is the ratio of the uptake values of the heart to mediastinum (H/M). This ratio will be a stable independent of the operators when the uptake value in the myocardium region is clearly higher than that in background, however, it will be unreliable indices when the myocardium region is unclear because of the low uptake values. This study aims to develop a new measurement method by using the image fusion of three modalities of MIBG scintigrams, 201-Tl scintigrams, and chest radiograms, to increase the reliability of the H/M measurement results. Our automated method consists of the following steps: (1) construct left ventricular (LV) map from 201-Tl myocardium image database, (2) determine heart region in chest radiograms, (3) determine mediastinum region in chest radiograms, (4) perform image fusion of chest radiograms and MIBG scintigrams, and 5) perform H/M measurements on MIBG scintigrams by using the locations of heart and mediastinum determined on the chest radiograms. We collected 165 cases with 201-Tl scintigrams and chest radiograms to construct the LV map. Another 65 cases with MIBG scintigrams and chest radiograms were also collected for the measurements. Four radiological technologists (RTs) manually measured the H/M in the MIBG images. We compared the four RTs’ results with our computer outputs by using Pearson’s correlation, the Bland-Altman method, and the equivalency test method. As a result, the correlations of the H/M between four the RTs and the computer were 0.85 to 0.88. We confirmed systematic errors between the four RTs and the computer as well as among the four RTs. The variation range of the H/M among the four RTs was obtained as 0.22 based on the equivalency test method. The computer outputs were existed within this range. We concluded that our image fusion method could measure equivalent values between the system and the RTs.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ryosuke Kawai, Takeshi Hara, Tetsuro Katafuchi, Tadahiko Ishihara , Xiangrong Zhou, Chisako Muramatsu, Yoshiteru Abe, and Hiroshi Fujita "Semi-automated measurements of heart-to-mediastinum ratio on 123I-MIBG myocardial scintigrams by using image fusion method with chest X-ray images", Proc. SPIE 9414, Medical Imaging 2015: Computer-Aided Diagnosis, 941433 (20 March 2015); https://doi.org/10.1117/12.2081630
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Chest

Image fusion

Heart

Image segmentation

Chest imaging

Lung

Neodymium

Back to Top