6 July 2018 Identification of breast tissue using the x-ray image measured with an energy-resolved cadmium telluride series detector based on photon-counting technique
Mariko Sasaki, Shuji Koyama, Yoshie Kodera, Reina Suzuki, Ai Nakajima, Hiroko Nishide, Mitsuhiro Mizutani, Megumi Watanabe, Naoko Yoshida, Hiroaki Hayashi, Tsutomu Yamakawa, Shuichiro Yamamoto, Daisuke Hashimoto, Masahiro Okada
Author Affiliations +
Proceedings Volume 10718, 14th International Workshop on Breast Imaging (IWBI 2018); 107181Z (2018) https://doi.org/10.1117/12.2317819
Event: The Fourteenth International Workshop on Breast Imaging, 2018, Atlanta, Georgia, United States
Abstract
We have been developing a new mammography device with a cadmium-telluride series energy-resolved photon-counting X-ray detector. Using a photon-counting technique, we examined the sensitivity of the system for differentiating the composition of breast tissue and detecting breast tumors. To differentiate breast tissues, we prepared surgically resected specimens fixed in formalin, consisting of adipose, mammary-gland, and tumor tissues. In order to obtain the values of certain effective atomic numbers, we prepared phantoms with 0%, 50% and 100% simulated mammary-gland tissue. In our imaging system, the X-ray spectrum penetrating the object was measured using three energy bins, and the products of linear attenuation coefficients and thicknesses for the three bins were calculated. These linear attenuation coefficients were properly corrected for beam hardening and normalized, to ignore the thickness. These calculations were applied for each pixel, and the gravity point per ROI (region of interest) was plotted on scatterplots to examine their distribution. Adiposetissue values were similar to known values; however, mammary-gland values were distant from expected values. In most specimens, the tumor points were focused; however, in some specimens, it was difficult to distinguish between tumor and mammary-gland tissues given their close linear attenuation coefficients. Mammary-gland tissues may have been influenced by formalin, given its tubular structure.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Mariko Sasaki, Shuji Koyama, Yoshie Kodera, Reina Suzuki, Ai Nakajima, Hiroko Nishide, Mitsuhiro Mizutani, Megumi Watanabe, Naoko Yoshida, Hiroaki Hayashi, Tsutomu Yamakawa, Shuichiro Yamamoto, Daisuke Hashimoto, and Masahiro Okada "Identification of breast tissue using the x-ray image measured with an energy-resolved cadmium telluride series detector based on photon-counting technique", Proc. SPIE 10718, 14th International Workshop on Breast Imaging (IWBI 2018), 107181Z (6 July 2018); https://doi.org/10.1117/12.2317819
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Breast

Tumors

Signal attenuation

X-rays

Sensors

X-ray imaging

Back to Top