16 April 1996 Evaluating the impact on operator performance of quantification algorithms
Ross Mitchell, Stephen J. Karlik, Donald H. Lee M.D., Michael Eliasziw, George P. Rice M.D., Aaron Fenster
Author Affiliations +
Abstract
Quantifying changes in the number and extent of lesions in MR images has been used to indicate disease activity in multiple sclerosis. However, quantification is often long and arduous. This has prompted research into new quantification and image processing algorithms to speed up and simplify lesion quantification. Nevertheless, many algorithms rely upon an experienced operator, and are thus subject to inter- and intra-operator variability. We present a new technique to measure operator variability which is largely independent of the lesions selected for analysis, and is expressed in the measurement units. This new measure allows researchers to predict and compare absolute uncertainty for operators using new algorithms. We used this technique to examine the impact on operator performance of computer assisted lesion quantification and anisotropic filtering of patient exams to reduce image noise. In both cases repeated measurements of lesions in MR exams were performed and analyzed. Results indicate that assisted quantification reduced inter-operator variability by half (from 0.34 cm3 to 0.17 cm3) and reduced intra-operator variability by one-third (from 0.23 cm3 to 0.15 cm3). Anisotropic filtering reduced inter- and intra-operator variability by one-fifth (from 0.34 cm3 to 0.27 cm3, and from 0.23 cm3 to 0.19 cm3, respectively). These results may have practical implications for clinical trials which rely on quantitative measurements to assess therapeutic effect.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ross Mitchell, Stephen J. Karlik, Donald H. Lee M.D., Michael Eliasziw, George P. Rice M.D., and Aaron Fenster "Evaluating the impact on operator performance of quantification algorithms", Proc. SPIE 2710, Medical Imaging 1996: Image Processing, (16 April 1996); https://doi.org/10.1117/12.237955
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reliability

Anisotropic filtering

Magnetic resonance imaging

Scanning electron microscopy

Image filtering

Diffusion

Error analysis

RELATED CONTENT

SAR analysis of the ice loss by marine terminating ice...
Proceedings of SPIE (October 14 2019)
Scale-based filtering of medical images
Proceedings of SPIE (June 06 2000)
Digital halftoning of medical images
Proceedings of SPIE (April 27 1995)

Back to Top