Paper
26 March 2008 3D inters-subject cardiac registration using 4D information
Alfredo Lopez, Karl D. Fritscher, Thomas Trieb, Rainer Schubert M.D., Julian Mattes
Author Affiliations +
Abstract
In this paper we present a new approach for the registration of cardiac 4D image sequences of different subjects, where we assume that a temporal association between the sequences is given. Moreover, we allow for one (or two) selected pair(s) of associated points in time of both sequences, which we call the bridging points in time, the use of additional information such as the semi-automatic segmentation of the investigated structure. We establish the 3D inter-subject registration for all other pairs of points in time exploiting (1) the inter-subject registration for the bridging pair of points in time, (2) the intra-subject motion calculation in both sequences with respect to the bridging pair, and (3) the concatenation of the obtained transformations. We formulate a cost functional integrating the similarity measures comparing the images of the bridging pair(s) of points in time and of the current pair of points in time, respectively. We evaluated our algorithm on 8 healthy volunteers leading to 28 inter-subject combinations and we analyze the behaviour for different parameter settings weighting differently the involved pairs of points in time. The approach based on the bridging pairs outperforms a direct 3D registration of corresponding points in time, in particular in the right ventricle we gain up to 33% in registration accuracy. Starting with a cost functional taking into account the similarity at the first bridging point in time, the results improve stepwise by integrating, firstly, information from the current pair of points in time and secondly, from a second bridging point in time. Our results also show a steep rise of the importance of regularization on the registration accuracy when registering the current point in time with our procedure (17% gain in accuracy) with respect to a direct registration in the bridging point (less than 1%). However, regularization during intra-sequence registration had only minor effects on the accuracy of our registration procedure.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Alfredo Lopez, Karl D. Fritscher, Thomas Trieb, Rainer Schubert M.D., and Julian Mattes "3D inters-subject cardiac registration using 4D information", Proc. SPIE 6914, Medical Imaging 2008: Image Processing, 691413 (26 March 2008); https://doi.org/10.1117/12.771386
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image registration

3D image processing

Image segmentation

3D acquisition

Heart

Astatine

Medical imaging

Back to Top