ABSTRACT
A key concern for a high-power processor is heat dissipation, which limits the power, and thus the operating frequencies, of chips so as not to exceed some temperature threshold. In particular, 3-D chip integration will further increase power density, thus requiring more efficient cooling technology. While air, fluorinert and mineral oil have been traditionally used as coolants, in this study, we propose to directly use tap or natural water due to its superior thermal conductivity. We have developed the "in-water computer" prototypes that rely on a parylene film insulation coating. Our prototypes can support direct water-immersion cooling by taking and draining natural water, while existing cooling requires the secondary coolant (e.g. outside air in cold climates) for cooling the primary coolants that contact chips. Our prototypes successfully reduce by 20 degrees the chip temperature of commodity processor chips. Our analysis results show that the in-water cooling increases the acceptable amount of power density of chips, thus achieving higher operating frequencies of chips. Through a full-system simulation, our results show that the water-immersion chip multiprocessors outperform the counterpart water-pipe cooled and oil-immersion chips by up to 14% and 4.5%, respectively, in terms of execution times of NAS Parallel Benchmarks.
- A Sridhar, A Vincenzi, M Ruggiero, T Brunschwiler, D Atienza. 2010. 3D-ICE: Fast compact transient thermal modeling for 3D-ICs with inter-tier liquid cooling. In Proceedings of the International Conference on Computer-Aided Design. 463--470. Google ScholarDigital Library
- Alex Kampl. 2014. Bitcoin 2-Phase Immersion Cooling and the Implications for High Performance Computing. Electronics Cooling Magazine (March 2014), 24--29.Google Scholar
- ANSYS CFX. 2019. https://www.ansys.com/products/fluids/ansys-cfx.Google Scholar
- N. Binkert, B. Beckmann, G. Black, S. K. Reinhardt, A. Saidi, A. Basu, J. Hestness, D. R. Hower, T. Krishna, S. Sardashti, R. Sen, K. Sewell, M. Shoaib, N. Vaish, M. D. Hill, and D. A. Wood. 2011. The gem5 Simulator. ACM SIGARCH Computer Architecture News 39, 2 (May 2011), 1--7. Google ScholarDigital Library
- D. Brooks and M. Martonosi. 2001. Dynamic Thermal Management for High-Performance Microprocessors. In International Symposium on High-Performance Computer Architecture (HPCA). 171--182. Google ScholarDigital Library
- G. Chen, J. Kuang, Z. Zeng, H. Zhang, E. F. Y. Young, and B. Yu. 2017. Minimizing Thermal Gradient and Pumping Power in 3D IC Liquid Cooling Network Design. In Design Automation Conference (DAC). 70:1--70:6. Google ScholarDigital Library
- J. Cong, J. Wei, and Y. Zhang. 2004. A Thermal-driven Floorplanning Algorithm for 3D ICs. In IEEE/ACM International Conference on Computer-aided Design (ICCAD). 306--313. Google ScholarDigital Library
- A. K. Coskun, T. S. Rosing, and K. Whisnant. 2007. Temperature aware task scheduling in MPSoCs. In Design, Automation and Test in Europe Conference and Exposition (DATE). 1659--1664. Google ScholarDigital Library
- T. Endo, A. Nukada, and S. Matsuoka. 2014. TSUBAME-KFC: A modern liquid submersion cooling prototype towards exascale becoming the greenest supercomputer in the world. In 20th IEEE International Conference on Parallel and Distributed Systems (ICPADS). 360--367.Google Scholar
- FloTHERM, Electronics thermal analysis software, Mentor Graphics. 2018. https://www.mentor.com/products/mechanical/flotherm/flotherm/.Google Scholar
- A. Fourmigue, G. Beltrame, and G. Nicolescu. 2014. Efficient transient thermal simulation of 3D ICs with liquid-cooling and through silicon vias. In Design, Automation & Test in Europe Conference & Exhibition(DATE). 1--6. Google ScholarDigital Library
- Green Revolution Cooling, white paper. 2015. Oil Submersion Cooling for Today's Data Centers. http://www.grcooling.com/wp-content/uploads/2015/06/GRC_WP-CLICK-Oil_Sub_DCc.pdf.Google Scholar
- T. Hanada, H. Sasaki, K. Inoue, and K. Murakami. 2011. Performance evaluation of 3D stacked multi-core processors with temperature consideration. In IEEE International 3D Systems Integration Conference (3DIC). 1--5.Google Scholar
- International Roadmap for Devices and Systems (IRDS). 2019. https://irds.ieee.org/.Google Scholar
- D.-C. Juan, S. Garg, and D. Marculescu. 2011. Statistical thermal evaluation and mitigation techniques for 3D Chip-Multiprocessors in the presence of process variations. In Design, Automation and Test in Europe, DATE. 383--388.Google Scholar
- T. Kagami, H. Matsutani, M. Koibuchi, Y. Take, T. Kuroda, and H. Amano. 2016. Efficient 3-D Bus Architectures for Inductive-Coupling ThruChip Interfaces. IEEE Trans. VLSI Syst. 24, 2 (2016), 493--506.Google ScholarDigital Library
- KISCO Ltd., diX Coating. 2014. http://www.kisco-net.com/business/dix-coating/.Google Scholar
- R.W. Knight, D.J. Hall, J.S. Goodling, and R.C. Jaeger. 1992. Heat sink optimization with application to microchannel. IEEE Transactions on Components, Hybrids, and Manufacturing Technology 15, 5 (1992), 832--842.Google ScholarCross Ref
- J.M. Koo, S. Im, L. Jiang, and K.E. Goodson. 2005. Integrated Microchannel Cooling for Three-Dimensional Circuit Architectures. ASME Journal of Heat Transfer 127 (2005), 49--58.Google ScholarCross Ref
- S. Li, J. H. Ahn, R. D. Strong, J. B. Brockman, D.M. Tullsen, and N. P. Jouppi. 2009. McPAT: An Integrated Power, Area, and Timing Modeling Framework for M ulticore and Manycore Architectures. In the IEEE/ACM International Symposium on Microarchitecture. 469--480. Google ScholarDigital Library
- M. Matsuda and K.Mashiko and Y. Saito and T. Nguyen and T. Nguyen. 2015. Micro-channel Cold Plate Units for Cooling Super Computer. Fujikura Technical Review 44 (March 2015), 53--57.Google Scholar
- Microsoft, Project Natick. 2018. http://natick.research.microsoft.com/.Google Scholar
- National Institute of Advanced Industrial Science and Technology (AIST), AI Bridging Cloud Infrastructure (ABCI). 2019. https://abci.ai/.Google Scholar
- R. Zhang and M. R. Stan and K. Skadron. 2015. HotSpot 6.0: Validation, Acceleration and Extension. University of Virginia, Tech. Report CS-2015-04.Google Scholar
- S. K. Roy, S. Mandal, C. Giri, and H. Rahaman. 2015. A thermal estimation model for 3D IC using liquid cooled microchannels and thermal TSVs. In IFIP/IEEE International Conference on Very Large Scale Integration, VLSI-SoC. 122--127.Google Scholar
- S. Zimmermann and I. Meijer and M. K. Tiwari and S. Paredes and B. Michel and D. Poulikakos. 2012. Aquasar: A hot water cooled data center with direct energy reuse. ENERGY 43 (July 2012), 237--245. Issue 1.Google Scholar
- K. Skadron, M. R. Stan, W. Huang, S. Velusamy, K. Sankaranarayanan, and D. Tarjan. 2003. Temperature-Aware Microarchitecture. In International Symposium on Computer Architecture (ISCA). 2--13. Google ScholarDigital Library
- A. Sridhar, M. M. Sabry, and D. Atienza. 2014. A Semi-Analytical Thermal Modeling Framework for Liquid-Cooled ICs. IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems 33, 8 (Aug 2014), 1145--1158.Google ScholarCross Ref
- Swiss National Supercomputing Centre. 2019. https://www.cscs.ch/publications/fact-sheets/lake-water-to-cool-supercomputers/.Google Scholar
- T. Totoki, HotSpot-6.0 Extension. 2019. https://github.com/KoibuchiLab/HotSpot-6.0-3D-API.Google Scholar
- D.B. Tuckerman and R.F.W. Pease. 1981. High-performance heat sinking for VLSI. IEEE Electron Device Letters EDL-2, 5 (1981), 126--129.Google ScholarCross Ref
Index Terms
- The Case for Water-Immersion Computer Boards
Recommendations
Fouling in Circulating Cooling Water System
ICBEB '12: Proceedings of the 2012 International Conference on Biomedical Engineering and BiotechnologyFouling exists in almost every circulating cooling water system. It greatly harms to the operation of the system. According to their formation, fouling can be classified into crystallization fouling, particulate fouling, chemical reaction fouling, ...
Comments