Acquisition Protocols to Optimize 68Ga-DOTA-NOC Position Emission Tomography/Computer Tomography Image Quality Based on Patient Body Mass Index and Injected Dose

Buy Article:

$107.14 + tax (Refund Policy)

Background: The choice of 68Ga-DOTA-1-Nal3-octreotide (68Ga-DOTA-NOC) injected dose and Position emission tomography/computer tomography (PET/CT) acquisition time is still a challenge for obtaining consistently high-quality PET image. Objective: To determine the optimal acquisition protocols based on patient body mass index (BMI) and the injected dose per kilogram for 68Ga-DOTA-NOC PET/CT imaging. Patients and Methods: This was a retrospective analysis of 51 patients (21 males and 30 females) who underwent clinical 68Ga-DOTANOC PET/CT imaging from November 2016 to March 2018 in Nanjing first hospital, the average BMI of these patients was 23.18 ± 3.45 kg/m2 with injected dose of 39.55–110.11 MBq. The study population was classified into groups based on Chinese standard BMI and injected dose. PET image quality and acquisition time were evaluated by coefficient of variance (CV) in the liver slice. Results: (1) The CV significantly increased with increasing weight and BMI (r = 0.647, 0.483, all P < 0.01), and significantly decreased with increasing injected dose per kilogram (r = 0 695, P < 0.01). (2) The CV differed significantly among 4 BMI-based groups, except for normal-weight group versus overweight group and overweight group versus obese group (P < 0.01), and the ratio of overweight group and obese group to normal weight group was approximately 1.1 and 1.2, respectively. Meanwhile, the CV had a significant statistical difference among 3 injected dose per kilogram groups (P < 0.01), and the ratio of that for low dose group and high dose group to moderate dose group was approximately 1.2 and 0.8. Conclusion: The findings showed a feasibility of obtaining consistently high-quality PET image at low injected dose and shorter acquisition time. Estimation of optimal acquisition time and injected dose using CV is valid in improving PET image quality, which can provide reference for the establishment and promotion of 68Ga-DOTA-NOC imaging protocols in China.

Keywords: 68GA-DOTA-NOC; ACQUISITION TIME; BMI; INJECTED DOSE; PET/CT

Document Type: Research Article

Publication date: 01 February 2020

More about this publication?
  • Journal of Medical Imaging and Health Informatics (JMIHI) is a medium to disseminate novel experimental and theoretical research results in the field of biomedicine, biology, clinical, rehabilitation engineering, medical image processing, bio-computing, D2H2, and other health related areas.
  • Editorial Board
  • Information for Authors
  • Subscribe to this Title
  • Ingenta Connect is not responsible for the content or availability of external websites
  • Access Key
  • Free content
  • Partial Free content
  • New content
  • Open access content
  • Partial Open access content
  • Subscribed content
  • Partial Subscribed content
  • Free trial content