2013 Volume E96.B Issue 9 Pages 2198-2205
Design equations for satisfying off-nominal operating conditions of the class E amplifier with a nonlinear shunt capacitance for a grading coefficient of 0.5 and the duty cycle D=0.5 are derived. By exploiting the off-nominal class E operation, various amplifier parameters such as input voltage, operating frequency, output power, and load resistance can be set as design specifications. As a result of the analysis in this paper, the following extension of the usability of the class E amplifier was achieved. With rising up the dc supply voltage, the shunt capacitance which achieves the off-nominal operation can be increased. This means that a transistor with higher output capacitance can be used for ZVS operation. This also means that maximum operating frequency which achieves ZVS can be increased. An example of a design procedure of the class E amplifier is given. The theoretical results were verified with an experiment.