Evaluation of a PAH/PSS Layer-by-Layer Deposited Film Using a Quartz-Crystal-Microbalance and Surface-Plasmon-Resonance Hybrid Sensor
Keisuke KAWACHIKazunari SHINBOYasuo OHDAIRAAkira BABAKeizo KATOFutao KANEKO
Author information
JOURNAL RESTRICTED ACCESS

2015 Volume E98.C Issue 2 Pages 136-138

Details
Abstract

A quartz-crystal-microbalance (QCM) and surface-plasmon-resonance (SPR) hybrid sensor was prepared, and the depositions of polymer electrolytes layer-by-layer (LbL) films were observed in situ. The estimated thicknesses obtained from the QCM method were different from those obtained from the SPR method. This was estimated to be caused by film swelling and water contained in the film.