Evaluation of Trihedral Corner Reflector for SAR Polarimetric Calibration
Shunichi KUSANOMotoyuki SATO
Author information
JOURNAL RESTRICTED ACCESS

2009 Volume E92.C Issue 1 Pages 112-115

Details
Abstract

A trihedral corner reflector is often used for SAR polarimetric calibration. However, the scattering property of the reflector used for the calibration may not be correct if the high frequency approximation is not satisfied or if an incident angle deviates from the symmetric axis of the reflector. In order to know the conditions for precise SAR polarimetric calibration, we evaluated the polarimetric response of the reflector by a numerical simulation using the method of moment (MoM). It is found that allowable incident angle deviation is 5 degree to azimuth direction and 4 degree to elevation direction for precise SAR polarimetric calibration when the size of the reflector is 7.5 times larger than the wavelength of an incident wave.