IEICE Transactions on Electronics
Online ISSN : 1745-1353
Print ISSN : 0916-8524
Regular Section
A Study on Temporal Dark Image Sticking in AC-PDP Using Vacuum-Sealing Method
Choon-Sang PARKHeung-Sik TAE
Author information
JOURNAL RESTRICTED ACCESS

2009 Volume E92.C Issue 1 Pages 161-165

Details
Abstract

Minimizing the residual impurity gases is a key factor for reducing temporal dark image sticking. Therefore, this paper uses a vacuum-sealing method that minimizes the residual impurity gases by enhancing the base vacuum level, and the resultant change in temporal dark image sticking is then examined in comparison to that with the conventional sealing method using 42-in. ac-PDPs with a high Xe (11%) content. As a result of monitoring the difference in the display luminance, infrared emission, and perceived luminance between the cells with and without temporal dark image sticking, the vacuum-sealing method is demonstrated to reduce temporal dark image sticking by decreasing the residual impurity gases and increasing the oxygen vacancy in the MgO layer. Furthermore, the use of a modified driving waveform along with the vacuum-sealing method is even more effective in reducing temporal dark image sticking.

Content from these authors
© 2009 The Institute of Electronics, Information and Communication Engineers
Previous article Next article
feedback
Top