Fouling monitoring in a thermosiphon reboiler | IEEE Conference Publication | IEEE Xplore

Fouling monitoring in a thermosiphon reboiler


Abstract:

The aim of this paper is to describe a system for fouling monitoring in thermosiphon reboilers. This system is based on a static model of the fouling resistance of which ...Show More

Abstract:

The aim of this paper is to describe a system for fouling monitoring in thermosiphon reboilers. This system is based on a static model of the fouling resistance of which the parameters are identified from industrial data. The determination of adequate data requires the detection of transients due to set point changes, physical disturbances or change in fouling, as well as the selection of sufficiently informative measurements. These two tasks are performed by combining statistical change detection tests, and a measure of information content in a suitable decision system. The effectiveness of the method is illustrated by processing industrial data.
Date of Conference: 04-07 September 2001
Date Added to IEEE Xplore: 27 April 2015
Print ISBN:978-3-9524173-6-2
Conference Location: Porto, Portugal

Contact IEEE to Subscribe

References

References is not available for this document.