Abstract:
This paper proposes a FDI strategy using high gain observers. Observers are often necessary for control purpose. It is possible to extend their application to disturbance...Show MoreMetadata
Abstract:
This paper proposes a FDI strategy using high gain observers. Observers are often necessary for control purpose. It is possible to extend their application to disturbance estimation and FDI strategy. The observer is designed for a performance study on an induction motor in the framework of a specific induction motor Fault Diagnosis Benchmark.
Published in: 2009 European Control Conference (ECC)
Date of Conference: 23-26 August 2009
Date Added to IEEE Xplore: 02 April 2015
Print ISBN:978-3-9524173-9-3