• KSII Transactions on Internet and Information Systems
    Monthly Online Journal (eISSN: 1976-7277)

Development and Evaluation of Tip Pinch Strength Measurement on a Paretic hand Rehabilitation Device


Abstract

In this study, we described the development of a methodology to measure tip-pinch strength on the paretic hand rehabilitation device and aimed to investigate reliability of the device. FSR sensors were embedded on the device, and tip pinch strength was estimated with data collected from the sensors using a developed equation while participants were demonstrating tip pinch. Reliability tests included inter-rater, test-retest, and inter-instrument reliability. B&L Engineering pinch gauge was utilized for the comparison. Thirty-seven healthy students participated in the experiment. Both inter-rater and test-retest reliability were excellent as Intraclass Correlation Coefficients (ICCs) were greater than 0.9 (p<0.01). There were no statistically significant differences in tip-pinch strengths. Inter-instrument reliability analysis confirmed good correlation between the two instruments (r = 0.88, p < 0.01). The findings of this study suggest that the two instruments are not interchangeable. However, the tip-pinch mechanism used in the paretic hand rehabilitation device is reliable that can be used to evaluate tip pinch strength in clinical environment and can provides a parameter that monitors changes in the hand functions.


Statistics

Show / Hide Statistics

Statistics (Cumulative Counts from December 1st, 2015)
Multiple requests among the same browser session are counted as one view.
If you mouse over a chart, the values of data points will be shown.


Cite this article

[IEEE Style]
J. Kim, Y. Cha, S. Lee, B. Jung, "Development and Evaluation of Tip Pinch Strength Measurement on a Paretic hand Rehabilitation Device," KSII Transactions on Internet and Information Systems, vol. 11, no. 2, pp. 1201-1216, 2017. DOI: 10.3837/tiis.2017.02.033.

[ACM Style]
Jung-Yeon Kim, Ye-Rin Cha, Sang-Heon Lee, and Bong-Keun Jung. 2017. Development and Evaluation of Tip Pinch Strength Measurement on a Paretic hand Rehabilitation Device. KSII Transactions on Internet and Information Systems, 11, 2, (2017), 1201-1216. DOI: 10.3837/tiis.2017.02.033.

[BibTeX Style]
@article{tiis:21380, title="Development and Evaluation of Tip Pinch Strength Measurement on a Paretic hand Rehabilitation Device", author="Jung-Yeon Kim and Ye-Rin Cha and Sang-Heon Lee and Bong-Keun Jung and ", journal="KSII Transactions on Internet and Information Systems", DOI={10.3837/tiis.2017.02.033}, volume={11}, number={2}, year="2017", month={February}, pages={1201-1216}}