Keyword(s): Noninvasive Measurement, Long-term Measurement, Core Temperature, Dual-Heat-Flux Method, Numeric Modeling, Experiment.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instruments and Devices ; Devices ; Health Monitoring Devices ; Human-Computer Interaction ; Physiological Computing Systems

Abstract: This paper describes the improvement of a transcutaneous core temperature thermometer by modifying the configuration, in terms of height and radius, of the thermometer using the so-called dual-heat-flux (DHF) method. The motivation of these modifications is to decrease the volume of the thermometer so as to reduce the transverse heat flow inside, in other words, to preserve the underlying assumption of the DHF method that heat flows from the inner part of human body through skin onto the thermometer longitudinally. The modification’s effect is evaluated by both numeric modeling based on finite element method and experiment. The results of simulations and experiments show that a lower-in-height and larger-in-radius configuration will improve the accuracy of the thermometer. Prototypes of 22.0 mm radius can attain satisfactory accuracy with error less than 0.5 C when heights are 8.0 mm or less.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.15.202.214

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Huang, M.; Tamura, T.; Chen, W.; Kitamura, K.; Nemoto, T. and Kanaya, S. (2014). Geometrical Improvement of a Noninvasive Core Temperature Thermometer based on Numeric Modeling and Experiment Validation. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2014) - BIODEVICES; ISBN 978-989-758-013-0; ISSN 2184-4305, SciTePress, pages 23-27. DOI: 10.5220/0004790000230027

@conference{biodevices14,
author={Ming Huang. and Toshiyo Tamura. and Wenxi Chen. and Kei{-}ichiro Kitamura. and Tetsu Nemoto. and Shigehiko Kanaya.},
title={Geometrical Improvement of a Noninvasive Core Temperature Thermometer based on Numeric Modeling and Experiment Validation},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2014) - BIODEVICES},
year={2014},
pages={23-27},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004790000230027},
isbn={978-989-758-013-0},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2014) - BIODEVICES
TI - Geometrical Improvement of a Noninvasive Core Temperature Thermometer based on Numeric Modeling and Experiment Validation
SN - 978-989-758-013-0
IS - 2184-4305
AU - Huang, M.
AU - Tamura, T.
AU - Chen, W.
AU - Kitamura, K.
AU - Nemoto, T.
AU - Kanaya, S.
PY - 2014
SP - 23
EP - 27
DO - 10.5220/0004790000230027
PB - SciTePress