loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Patrizio Barca 1 ; 2 ; Marco Giannelli 3 ; Maria Evelina Fantacci 1 ; 2 and Davide Caramella 3

Affiliations: 1 University of Pisa, Italy ; 2 Pisa Section, Italy ; 3 Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”, Italy

Keyword(s): CT Iterative Reconstruction, ASIR, Image Quality, NPS, CNR, MTF.

Abstract: X-ray Computed Tomography (CT) is an essential imaging technique for different diagnostic and therapeutic tasks. However, ionizing radiation from CT scanners represents the largest source of medical exposure for the population of industrialized countries. In order to reduce CT dose during patient examination, iterative reconstruction algorithms have been developed to help existing dose reduction methods. In this paper, we studied the image quality performance of a 64-slice CT scanner (Optima CT660, GE Healthcare, Waukesha, WI, USA) that implements both the conventional filtered back-projection (FBP) and the Adaptive Statistical Iterative Reconstruction (ASIR, GE Healthcare, Waukesha, WI, USA) algorithm. In order to compare the performance of these two reconstruction technologies, CT images of the Catphan®504 phantom were reconstructed using both conventional FBP and ASIR with different percentages of reconstruction from 20% to 100%. Noise level, noise power spectrum (NPS), contrast-t o-noise ratio (CNR) and modulation transfer function (MTF) were estimated for different values of the main radiation exposure parameters (i.e. mAs, kVp, pitch and slice thickness) and contrast objects. We found that, as compared to conventional FBP, noise/CNR decreases/increases non-linearly up to 50%/100% when increasing the ASIR blending level of reconstruction. Furthermore, ASIR modifies the NPS curve shape (i.e. the noise texture). The MTF for ASIR-reconstructed images depended on both tube load and contrast level, whereas MTF of FBP-reconstructed images did not. For lower tube load and contrast level, ASIR offered lower performance as compared to conventional FBP in terms of reduced spatial resolution and MTF decreased with increasing ASIR blending level of reconstruction. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.19.56.45

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Barca, P.; Giannelli, M.; Fantacci, M. and Caramella, D. (2017). Evaluation of the Imaging Properties of a CT Scanner with the Adaptive Statistical Iterative Reconstruction Algorithm. In Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017) - BIODEVICES; ISBN 978-989-758-216-5; ISSN 2184-4305, SciTePress, pages 200-206. DOI: 10.5220/0006240802000206

@conference{biodevices17,
author={Patrizio Barca. and Marco Giannelli. and Maria Evelina Fantacci. and Davide Caramella.},
title={Evaluation of the Imaging Properties of a CT Scanner with the Adaptive Statistical Iterative Reconstruction Algorithm},
booktitle={Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017) - BIODEVICES},
year={2017},
pages={200-206},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006240802000206},
isbn={978-989-758-216-5},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017) - BIODEVICES
TI - Evaluation of the Imaging Properties of a CT Scanner with the Adaptive Statistical Iterative Reconstruction Algorithm
SN - 978-989-758-216-5
IS - 2184-4305
AU - Barca, P.
AU - Giannelli, M.
AU - Fantacci, M.
AU - Caramella, D.
PY - 2017
SP - 200
EP - 206
DO - 10.5220/0006240802000206
PB - SciTePress