Skip to main content

Coil Sensitivity Estimation for Optimal SNR Reconstruction and Intensity Inhomogeneity Correction in Phased Array MR Imaging

  • Conference paper
Information Processing in Medical Imaging (IPMI 2005)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 3565))

Abstract

Magnetic resonance (MR) images can be acquired by multiple receiver coil systems to improve signal-to-noise ratio (SNR) and to decrease acquisition time. The optimal SNR images can be reconstructed from the coil data when the coil sensitivities are known. In typical MR imaging studies, the information about coil sensitivity profiles is not available. In such cases the sum-of-squares (SoS) reconstruction algorithm is usually applied. The intensity of the SoS reconstructed image is modulated by a spatially variable function due to the non-uniformity of coil sensitivities. Additionally, the SoS images also have sub-optimal SNR and bias in image intensity. All these effects might introduce errors when quantitative analysis and/or tissue segmentation are performed on the SoS reconstructed images. In this paper, we present an iterative algorithm for coil sensitivity estimation and demonstrate its applicability for optimal SNR reconstruction and intensity inhomogeneity correction in phased array MR imaging.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Roemer, P.B., Edelstein, W.A., Hayes, C.E., Souza, S.P., Mueller, O.M.: The NMR Phased-Array. Magnetic Resonance in Medicine 16, 192–225 (1990)

    Article  Google Scholar 

  2. Murakami, J.W., Hayes, C.E., Weinberger, E.: Intensity Correction of Phased-Array Sur-face Coil Images. Magnetic Resonance in Medicine 35, 585–590 (1996)

    Article  Google Scholar 

  3. Meyer, C.R., Bland, P.H., Pipe, J.: Retrospective Correction of Intensity Inhomogeneities in MRI. IEEE Transactions on Medical Imaging 14, 36–41 (1995)

    Article  Google Scholar 

  4. Sled, J.G., Zijdenbos, A.P., Evans, A.C.: A Nonparametric Method for Automatic Correc-tion of Intensity Non-uniformity in MRI data. IEEE Transactions on Medical Imaging 17, 87–97 (1998)

    Article  Google Scholar 

  5. Han, C., Hatsukami, T.S., Yuan, C.: A Multi-scale Method for Automatic Correction of In-tensity Non-Uniformity in MR Images. Journal of Magnetic Resonance Imaging 13, 428–436 (2001)

    Article  Google Scholar 

  6. Vokurka, E.A., Thacker, N.A., Jackson, A.: A Fast Model Independent Method for Auto-matic Correction of Intensity Non-uniformity in MRI Data. Journal of Magnetic Reso-nance Imaging 10, 550–562 (1999)

    Article  Google Scholar 

  7. Smythe, W.R.: Static and Dynamic Electricity. McGraw Hill, New York (1968)

    Google Scholar 

  8. Gudbjartsson, H., Patz, P.: The Rician Distribution of Noisy MRI Data. Magnetic Reso-nance in Medicine 34, 910–914 (1995)

    Article  Google Scholar 

  9. Ahn, C.B., Cho, Z.H.: A New Phase Correction Method in NMR Imaging Based on Auto-correlation and Histogram Analysis. IEEE Transactions on Medical Imaging 6, 32–36 (1987)

    Article  Google Scholar 

  10. Pruessmann, K.P., Weiger, M., Scheidegger, M.B., Boesiger, P.: SENSE: Sensitivity En-coding for Fast MRI. Magnetic Resonance in Medicine 42, 952–962 (1999)

    Article  Google Scholar 

  11. Liang, Z., MacFall, J.R., Harrington, D.P.: Parameter Estimation and Tissue Segmentation from Multispectral MR images. IEEE Transactions on Medical Imaging 13, 441–449 (1994)

    Article  Google Scholar 

  12. Wells, W.M., Grimson, W.E.L., Kikinis, R., Jolesz, F.A.: Adaptive Segmentation of MRI Data. IEEE Transactions on Medical Imaging 15, 429–442 (1996)

    Article  Google Scholar 

  13. Wilson, D.L., Noble, J.A.: An Adaptive Segmentation Algorithm of Time-of-flight MRA Data. IEEE Transactions on Medical Imaging 18, 938–945 (1999)

    Article  Google Scholar 

  14. Press, W.H., Flannery, B.P., Teukolsky, S.A., Vetterling, W.T.: Numerical Recipes in C: The Art of Scientific Computing. Cambridge University Press, New York (1996)

    Google Scholar 

  15. Kim, S.E., Kholmovski, E.G., Jeong, E.K., Buswell, H.R., Tsuruda, J.S., Parker, D.L.: Tri-ple Contrast Technique for Black Blood Imaging with Double Inversion Preparation. Mag-netic Resonance in Medicine 52, 1379–1387 (2004)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2005 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Vemuri, P., Kholmovski, E.G., Parker, D.L., Chapman, B.E. (2005). Coil Sensitivity Estimation for Optimal SNR Reconstruction and Intensity Inhomogeneity Correction in Phased Array MR Imaging. In: Christensen, G.E., Sonka, M. (eds) Information Processing in Medical Imaging. IPMI 2005. Lecture Notes in Computer Science, vol 3565. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11505730_50

Download citation

  • DOI: https://doi.org/10.1007/11505730_50

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-26545-0

  • Online ISBN: 978-3-540-31676-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics