Abstract
Many computer aided diagnosis schemes in chest radiography start with preprocessing steps that try to remove or suppress normal anatomical structures from the image. Examples of normal structures in posteroanterior chest radiographs are bony structures. Removing these kinds of structures can be done quite effectively if the right dual energy images—two radiographic images from the same patient taken with different energies—are available. Subtracting these two radiographs gives a soft-tissue image with most of the rib and other bony structures removed. In general, however, dual energy images are not readily available.
We propose a supervised learning technique for inferring a soft-tissue image from a standard radiograph without explicitly determining the additional dual energy image. The procedure, called dual energy faking, is based on k-nearest neighbor regression, and incorporates knowledge obtained from a training set of dual energy radiographs with their corresponding subtraction images for the construction of a soft-tissue image from a previously unseen single standard chest image.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Shah, P.K., Austin, J.H.M., White, C.S., Patel, P., Haramati, L.B., Pearson, G.D.N., Shiau, M.C., Berkmen, Y.M.: Missed non-small cell lung cancer: Radiographic findings of potentially resectable lesions evident only in retrospect. Radiology 226(3), 235–241 (2003)
Fischbach, F., Freund, T., Röttgen, R., Engert, U., Felix, R., Ricke, J.: Dual-energy chest radiography with a flat-panel digital detector: Revealing calcified chest abnormalities. American Journal of Roentgenology 181, 1519–1524 (2003)
Warp, R.J., Dobbins III, J.T.: Quantitative evaluation of noise reduction strategies in dual-energy imaging. Medical Physics 30(2), 190–198 (2003)
Loog, M.: Supervised dimensionality reduction and contextual pattern recognition in medical image processing. Ph.D. Thesis, Image Sciences Institute, Utrecht University, The Netherlands (2004)
Kano, A., Doi, K., MacMahon, H., Hassell, D., Giger, M.: Digital image subtraction of temporally sequential chest images for detection of interval change. Medical Physics 21(3), 453–461 (1994)
Katsuragawa, S., Tagashira, H., Li, Q., MacMahon, H., Doi, K.: Comparison of quality of temporal subtraction images obtained with manual and automated methods of digital chest radiography. Journal of Digital Imaging 12(4), 166–172 (1999)
Loeckx, D., Maes, F., Vandermeulen, D., Suetens, P.: Temporal subtraction of thorax CR images using a statistical deformation model. IEEE Transactions on Medical Imaging 22(11), 1490–1504 (2003)
Li, Q., Katsuragawa, S., Ishida, T., Yoshida, H., Tsukuda, S., MacMahon, H., Doi, K.: Contralateral subtraction: A novel technique for detection of asymmetric abnormalities on digital chest radiographs. Medical Physics 27(1), 47–55 (2000)
Shiraishi, J., Katsuragawa, S., Ikezoe, J., Matsumoto, T., Kobayashi, T., Komatsu, K., Matsui, M., Fujita, H., Kodera, Y., Doi, K.: Development of a digital image database for chest radiographs with and without a lung nodule: Receiver operating characteristic analysis of radiologists’ detection of pulmonary nodules. American Journal of Roentgenology 174, 71–74 (2000)
Ginneken, B., Haar Romeny, B., Viergever, M.A.: Computer-aided diagnosis in chest radiography: A survey. IEEE Transactions on Medical Imaging 20(12), 1228–1241 (2001)
Florack, L.M.J.: Image Structure. In: Computational Imaging and Vision, vol. 10. Kluwer Academic Publishers, Boston (1997)
Lindeberg, T.: Scale-Space Theory in Computer Vision. Kluwer Academic Press, Boston (1994)
Devroye, L., Györfi, L., Lugosi, G.: A Probabilistic Theory of Pattern Recognition. Springer, Heidelberg (1996)
Edwards, A.L.: Multiple Regression and the Analysis of Variance and Covariance. W. H. Freeman, San Francisco (1979)
Rice, J.A.: Mathematical Statistics and Data Analysis, 2nd edn. Duxbury Press, Belmont (1995)
Ginneken, B., Katsuragawa, S., ter Haar Romeny, B., Doi, K., Viergever, M.: Automatic detection of abnormalities in chest radiographs using local texture analysis. IEEE Transactions on Medical Imaging 21(2), 139–149 (2002)
MacMahon, H.: Clinical application of CAD in the chest. In: Computer-Aided Diagnosis in Medical Imaging. International Congress Series, vol. 1182, pp. 23–34 (1999)
Schilham, A.M.R., van Ginneken, B., Loog, M.: Multi-scale nodule detection in chest radiographs. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2878, pp. 602–609. Springer, Heidelberg (2003)
Xu, X.W., MacMahon, H., Doi, K.: Detection of lung nodule on digital energy subtracted soft-tissue and conventional chest images from a CR system. In: Computer-Aided Diagnosis in Medical Imaging. International Congress Series, vol. 1182, pp. 63–70 (1999)
Eskicioglu, A.M., Fisher, P.S.: Image quality measures and their performance. IEEE Transactions on Communications 43(12), 2959–2965 (1995)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2006 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Loog, M., van Ginneken, B. (2006). Bony Structure Suppression in Chest Radiographs. In: Beichel, R.R., Sonka, M. (eds) Computer Vision Approaches to Medical Image Analysis. CVAMIA 2006. Lecture Notes in Computer Science, vol 4241. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11889762_15
Download citation
DOI: https://doi.org/10.1007/11889762_15
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-46257-6
Online ISBN: 978-3-540-46258-3
eBook Packages: Computer ScienceComputer Science (R0)