Skip to main content

Automated Detection of the Left Ventricle from 4D MR Images: Validation Using Large Clinical Datasets

  • Conference paper
Advances in Image and Video Technology (PSIVT 2006)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 4319))

Included in the following conference series:

Abstract

We present a fully automated method to estimate the location and orientation of the left ventricle (LV) from four-dimensional (4D) cardiac magnetic resonance (CMR) images without requiring user input. The method is based on low-level image processing techniques which incorporate anatomical knowledge and is able to provide rapid, robust feedback for automated scan planning or further processing. The method relies on a novel combination of temporal Fourier analysis of image cines and simple contour detection to achieve a fast localization of the heart. Quantitative validation was performed using two 4D CMR datasets containing 395 patients (63720 images), with a range of cardiac and vascular disease, by comparing manual location with the automatic results. The method failed in only one case, and showed an average bias of better than 5mm in the apical, mid-ventricular and basal slices in the remaining 394. The errors in the automatically detected LV orientation were similar to those found in scan planning when performed by experienced technicians.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Santarelli, M., Positano, V., Michelassi, C., Lombardi, M., Landini, L.: Automated cardiac MR image segmentation: theory and measurement evaluation. Med. Eng. Phys. 25, 149–159 (2003)

    Article  Google Scholar 

  2. Lorenzo-Valdés, M., Sanchez-Ortiz, G., Mohiaddin, R., Rueckert, D.: Segmentation of 4D cardiac MR images using a probabilistic atlas and the EM algorithm. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2878, pp. 440–450. Springer, Heidelberg (2003)

    Chapter  Google Scholar 

  3. Mitchell, S., Bosch, J., Lelieveldt, B., van der Geest, R., Reiber, J., Sonka, M.: 3-D active appearance models: Segmentation of cardiac MR and ultrasound images. IEEE Trans. Med. Imag. 21(9), 1167–1178 (2002)

    Article  Google Scholar 

  4. Kaus, M.R., von Berg, J., Niessen, W., Pekar, V.: Automated segmentation of the left ventricle in cardiac MRI. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2878, pp. 432–439. Springer, Heidelberg (2003)

    Chapter  Google Scholar 

  5. Montillo, A., Metaxas, D., Axel, L.: Automated segmentation of the left and right ventricles in cardiac SPAMM images. In: Dohi, T., Kikinis, R. (eds.) MICCAI 2002. LNCS, vol. 2488, pp. 620–633. Springer, Heidelberg (2002)

    Chapter  Google Scholar 

  6. Spreeuwers, L., Breeuwer, M.: Automatic detection of the myocardial boundaries of the right and left ventricle. SPIE: Med. Imag. 4322, 1207–1217 (2001)

    Google Scholar 

  7. Danilouchkine, M., Westenberg, J., Reiber, J., Lelieveldt, B.: Accuracy of short-axis cardiac MRI automatically derived from scout acquisitions in free-breathing and breath-holding modes. MAGMA 18, 7–18 (2005)

    Article  Google Scholar 

  8. Jackson, C., Robson, M., Francis, J., Noble, J.: Automatic planning of the acquisition of cardiac MR images. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2878, pp. 541–548. Springer, Heidelberg (2003)

    Chapter  Google Scholar 

  9. Anderson, C.: Rationale and design of the cardiac magnetic resonance imaging substudy of the ONTARGET trial programme. J. Int. Med. Res. 33(4), 50–57 (2005)

    Google Scholar 

  10. Young, A., Cowan, B., Thrupp, S., Hedley, W., Dell’Italia, L.: Left ventricular mass and volume: fast calculation with guide-point modeling on MR images. Radiology 216, 597–602 (2000)

    Google Scholar 

  11. Sörgel, W., Vaerman, V.: Automatic heart localization from 4D MRI datasets. SPIE: Med. Imag. 3034, 333–344 (1997)

    Google Scholar 

  12. Gering, D.: Automatic segmentation of cardiac MRI. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2878, pp. 524–532. Springer, Heidelberg (2003)

    Chapter  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2006 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Lin, X., Cowan, B., Young, A. (2006). Automated Detection of the Left Ventricle from 4D MR Images: Validation Using Large Clinical Datasets. In: Chang, LW., Lie, WN. (eds) Advances in Image and Video Technology. PSIVT 2006. Lecture Notes in Computer Science, vol 4319. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11949534_22

Download citation

  • DOI: https://doi.org/10.1007/11949534_22

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-68297-4

  • Online ISBN: 978-3-540-68298-1

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics