Skip to main content

Cone beam imaging of a section of a long object with a short detector

  • Posters
  • Conference paper
  • First Online:
Information Processing in Medical Imaging (IPMI 1997)

Part of the book series: Lecture Notes in Computer Science ((LNCS,volume 1230))

  • 389 Accesses

Abstract

Imaging a sectional region within an object with a detector just big enough to cover the sectional region-of-interest is analyzed. We show that with some suitable choice of scanning configuration and with an innovative method of data combination, all the Radon data can be obtained accurately. The algorithm is mathematically exact, and requires no iterations and no additional measurements. The method can be applied to inspect portions of large industrial objects in industrial imaging, as well as to image portions of human bodies in medical diagnosis.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. R. Clack and M. Defrise, “Overview of reconstruction algorithms for exact cone-beam tomography”, Proc. SPIE Vol. 2299, 1994, pp. 230–241.

    Google Scholar 

  2. K.C. Tam, “Exact image reconstruction in cone beam 3D CT”, Review of Progress in Quantitative Non-Destructive Evaluation, Eds. D.O. Thompson and D.E. Chimenti (New York: Plenum Press) Vol. 4A, pp. 657–664).

    Google Scholar 

  3. J. Chen, “A theoretical framework of regional cone-beam tomography”, IEEE Trans.Med. Imag., MI-11 (1992) 342.

    Google Scholar 

  4. H. Kudo, T. Saito, “An extended completeness condition for exact cone-beam reconstruction and its application”, IEEE Conf. Record 1994 Nuclear Science Symposium and Medical Imaging Conference, Norfolk, VA, 1710–14, 1995.

    Google Scholar 

  5. K.C. Tam, “Method and apparatus for acquiring complete Radon data for exactly reconstructing a three dimensional computerized tomography image of a portion of an object irradiated by a cone beam source”, US. Patent 5,383,119, Jan 17, 1995.

    Google Scholar 

  6. K.C. Tam, “Helical and circle scan region of interest computerized tomography”, US. Patent 5,463,666, Oct 31, 1995.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

James Duncan Gene Gindi

Rights and permissions

Reprints and permissions

Copyright information

© 1997 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Tam, K.C. (1997). Cone beam imaging of a section of a long object with a short detector. In: Duncan, J., Gindi, G. (eds) Information Processing in Medical Imaging. IPMI 1997. Lecture Notes in Computer Science, vol 1230. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-63046-5_54

Download citation

  • DOI: https://doi.org/10.1007/3-540-63046-5_54

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-63046-3

  • Online ISBN: 978-3-540-69070-2

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics