Abstract
Continuous glucose monitors generate significant volumes of high frequency blood glucose data. Analysis of this data by a physician may entail the calculation of various glycemic variability metrics. In this paper, we consider the problem of metric robustness to sensor dropouts. We show that the standard metrics for glycemic variability are unreliable with missing data. A more recent metric, glycemic variability percentage, is shown to consistently underestimate glycemic variability as the amount of missing data increases. We therefore propose a new algorithm based on random sampling combined with linear regression to correct this underestimation, and show that the metric’s accuracy is significantly increased with our correction.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Bruen, D., Delaney, C., Florea, L., Diamond, D.: Glucose sensing for diabetes monitoring: recent developments. Sensors 17(8), 1866 (2017)
Buckingham, B., et al.: Effectiveness of early intensive therapy on \(\beta \)-cell preservation in type 1 diabetes. Diabetes Care 36, 4030 (2013)
Cox, D.J., Gonder-Frederick, L., Ritterband, L., Clarke, W., Kovatchev, B.P.: Prediction of severe hypoglycemia. Diabetes Care 30(6), 1370–1373 (2007). https://doi.org/10.2337/dc06-1386. http://care.diabetesjournals.org/content/30/6/1370
Danne, T., et al.: International consensus on use of continuous glucose monitoring. Diabetes Care 40(12), 1631–1640 (2017). https://doi.org/10.2337/dc17-1600. http://care.diabetesjournals.org/content/40/12/1631
Fabris, C., Patek, S.D., Breton, M.D.: Are risk indices derived from CGM interchangeable with SMBG-based indices? J. Diabetes Sci. Technol. 10(1), 50–59 (2016). https://doi.org/10.1177/1932296815599177
Hirsch, I.B., Balo, A.K., Sayer, K., Garcia, A., Buckingham, B.A., Peyser, T.A.: A simple composite metric for the assessment of glycemic status from continuous glucose monitoring data: implications for clinical practice and the artificial pancreas. Diabetes Technol. Ther. 19(S3), S-38–S-48 (2017). https://doi.org/10.1089/dia.2017.0080
Kovatchev, B.P., Cox, D.J., Gonder-Frederick, L.A., Clarke, W.: Symmetrization of the blood glucose measurement scale and its applications. Diabetes Care 20(11), 1655–1658 (1997)
Kovatchev, B.P., Straume, M., Cox, D.J., Farhy, L.S.: Risk analysis of blood glucose data: a quantitative approach to optimizing the control of insulin dependent diabetes. J. Theor. Med. 3(1), 1–10 (2000). https://doi.org/10.1080/10273660008833060
Pedregosa, F., et al.: Scikit-learn: machine learning in Python. J. Mach. Learn. Res. 12, 2825–2830 (2011)
Peyser, T.A., Balo, A.K., Buckingham, B.A., Hirsch, I.B., Garcia, A.: Glycemic variability percentage: a novel method for assessing glycemic variability from continuous glucose monitor data. Diabetes Technol. Ther. 20(1), 6–16 (2018). https://doi.org/10.1089/dia.2017.0187
The Nightscout Foundation: About the Nightscout Data Commons on Open Humans (2014). http://www.nightscoutfoundation.org/data-commons/
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Mayo, M. (2019). Improving the Robustness of the Glycemic Variability Percentage Metric to Sensor Dropouts in Continuous Glucose Monitor Data. In: Nguyen, N., Gaol, F., Hong, TP., Trawiński, B. (eds) Intelligent Information and Database Systems. ACIIDS 2019. Lecture Notes in Computer Science(), vol 11432. Springer, Cham. https://doi.org/10.1007/978-3-030-14802-7_32
Download citation
DOI: https://doi.org/10.1007/978-3-030-14802-7_32
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-14801-0
Online ISBN: 978-3-030-14802-7
eBook Packages: Computer ScienceComputer Science (R0)