Abstract
We have developed gaze detection systems based on the pupil-corneal reflection method for driver monitoring, digital signage, and so on. However, when a user looks at angularly remote positions (>±30° – ±40°) on a monitor screen from the optical systems for the gaze detection, the gaze detection becomes impossible because the corneal reflection does not appear. In the present paper, to expand the measurable horizontal range of the gaze, we proposed a method combing the pupil-corneal reflection method and the pupil ellipticity method. These two types of the gaze detection methods functioned on the same platform. In this combined method, a line of sight was always calculated using the ellipticity of the pupil ellipse and the inclination of the minor axis of the pupil ellipse. When the angle of the line of sight exceeded 30°, the gaze detection was determined using the pupil ellipticity method. When it was 30° or less, the pupil-corneal reflection method was used. When the pupil ellipticity method is used, it is unclear which direction a subject looks on the minor axis of the ellipse, e.g., right or left. To solve this problem, we proposed a method utilizing the difference in the pupil ellipticity between the right and left camera images. In the experiment, subjects were asked to look at 27 visual targets evenly arranged on horizontally arranged three monitors’ screens. The experimental result showed that the measurable range of the gaze detection was expanded into approximately ±45° horizontally by the combination of the two types of the gaze detection methods. In the total range, the average angular gaze error for all subjects was 2.02 ± 1.38°.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Fukumoto, K., Tsuzuki, T., Ebisawa, Y.: Improvement of accuracy in remote gaze detection for user wearing eyeglasses using relative position between centers of pupil and corneal sphere. In: Kurosu, M. (ed.) HCI 2015. LNCS, vol. 9170, pp. 13–23. Springer, Cham (2015). https://doi.org/10.1007/978-3-319-20916-6_2
Lai, C.C., Shih, S.W., Hung, Y.P.: Hybrid method for 3-D gaze tracking using glint and contour features. IEEE Trans. Circ. Syst. Video Technol. 25(1), 24–37 (2015)
Ebisawa, Y., Fukumoto, K.: Head-free, remote gaze detection system based on pupil-corneal reflection method with using two video cameras – one-point and nonlinear calibrations. In: Kurosu, M. (ed.) HCI 2013. LNCS, vol. 8007, pp. 205–214. Springer, Heidelberg (2013). https://doi.org/10.1007/978-3-642-39330-3_22
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Ebisawa, Y., Fukumoto, K., Nakazawa, Y. (2019). Horizontal Wide-Range Gaze Detection System by Combination of Pupil Ellipticity and Pupil-Corneal Reflection Methods. In: Stephanidis, C. (eds) HCI International 2019 - Posters. HCII 2019. Communications in Computer and Information Science, vol 1032. Springer, Cham. https://doi.org/10.1007/978-3-030-23522-2_19
Download citation
DOI: https://doi.org/10.1007/978-3-030-23522-2_19
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-23521-5
Online ISBN: 978-3-030-23522-2
eBook Packages: Computer ScienceComputer Science (R0)