Automatic Detection of the Carotid Artery Position for Blind Echo-Doppler Blood Flow Investigation

  • Conference paper
  • First Online:
Applications in Electronics Pervading Industry, Environment and Society (ApplePies 2019)

Abstract

Ultrasound instrumentation is widely employed in everyday clinical practice. Skilled operators, usually trained sonographers, operate the echograph and the ultrasonic probe to acquire B-mode images showing internal tissues/organs morphology, and echo-Doppler images with detailed information about blood flow. Unfortunately, skilled personnel are not always available, in particular in points-of-care distributed in rural areas or developing countries. Echographic systems capable of being operated from non-trained users can be valuable. In this work, an automatic blind procedure for detecting the position of the carotid artery is proposed. The untrained user places the probe transversally on the patient neck and starts the procedure. The machine automatically detects the carotid lumen in the B-mode image and selects its center, which can be used to extract Echo-Doppler data. The method was implemented in the ULA-OP experimental scanner and tested on healthy volunteers.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Evans DH, McDicken WN (2000) Doppler ultrasound physics, instrumentation and signal processing. Wiley, Chichester. ISBN: 978-0471970019

    Google Scholar 

  2. Urban G, Vergani P, Ghidini A, Tortoli P, Ricci S, Patrizio P, Paidas MJ (2007) State of the art: non-invasive ultrasound assessment of the uteroplacental circulation. Semin Perinatol 31(4):232–239. https://doi.org/10.1053/j.semperi.2007.06.002

    Article  Google Scholar 

  3. Grant E, Benson C, Moneta G et al (2003) Carotid artery stenosis: gray-scale and doppler US diagnosis—society of radiologists in ultrasound consensus conference. Radiology 229(2):340–346. https://doi.org/10.1148/radiol.2292030516

    Article  Google Scholar 

  4. Huang CC, Lee PY, Chen PY, Liu TY (2012) Design and implementation of a smartphone-based portable ultrasound pulsed-wave doppler device for blood flow measurement. IEEE Trans Ultrason Ferroelectr Freq Control 59(1):182–188. https://doi.org/10.1109/tuffc.2012.2171

  5. Duda RO, Hart PE (1972) Use of the Hough transformation to detect lines and curves in pictures. Commun ACM 15(1):11–15. https://doi.org/10.1145/361237.361242

    Article  MATH  Google Scholar 

  6. Tortoli P, Bassi L, Boni E, Dallai A, Guidi F, Ricci S (2009) ULA-OP: an advanced open platform for ultrasound research. IEEE Trans Ultrason Ferroelectr Freq Control 56(10):2207–2216, https://doi.org/10.1109/tuffc.2009.1303

  7. Tortoli P, Guidi G, Pignoli P (1993) Transverse Doppler spectral analysis for a correct interpretation of flow sonograms. Ultrasound Med Biol 19(2):115–121. https://doi.org/10.1016/0301-5629(93)90003-7

    Article  Google Scholar 

  8. Di Palma V et al (2019) “Medical assistance in contextual awareness” (AMICO): a project for a better cardiopathic patients quality of care. In: Proceedings of IEEE international workshop on advances in sensors and interfaces (IWASI), Otranto, June 2019. https://doi.org/10.1109/iwasi.2019.8791308

  9. Ricci S, Ramalli A, Bassi L, Boni E, Tortoli P (2018) Real-time blood velocity vector measurement over a 2D region. IEEE Trans Ultrason Ferroelectr Freq Control 65(2):201–209. https://doi.org/10.1109/tuffc.2017.2781715

  10. Song I, Yoon J, Kang J, Kim M, Jang WS, Shin NH, Yoo Y (2019) Design and implementation of a new wireless carotid neckband Doppler system with wearable ultrasound sensors: preliminary results. Appl Sci 9:2202. https://doi.org/10.3390/app9112202

    Article  Google Scholar 

Download references

Acknowledgements

Authors thank Prof. Piero Tortoli for the valuable advices that contributed to improve the paper. This work is part of the AMICO project funded from the National Programs (PON) of the Italian Ministry of Education, Universities and Research (MIUR): code ARS01_00900 (Decree n. 1989, 26 July 2018).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Stefano Ricci .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Matera, R., Ricci, S. (2020). Automatic Detection of the Carotid Artery Position for Blind Echo-Doppler Blood Flow Investigation. In: Saponara, S., De Gloria, A. (eds) Applications in Electronics Pervading Industry, Environment and Society. ApplePies 2019. Lecture Notes in Electrical Engineering, vol 627. Springer, Cham. https://doi.org/10.1007/978-3-030-37277-4_61

Download citation

Publish with us

Policies and ethics