Abstract
One of the most relevant aspects investigated by the scientific community in the healthcare field is the detection of vital parameters, such as the heart rate, through the use of contactless technologies, often considered more comfortable and unobtrusive for the subjects in exam. In particular, the main goal is to develop real-time oriented algorithms able to minimize the errors and to obtain results as close as possible to those achieved by clinical instruments, especially with the aim of carrying out a constant home monitoring for the elderly. In this paper two contactless methodologies for the heart rate estimation are analyzed, exploiting different approaches. In the first we first apply face recognition methods on RGB videos, and we then use well known algorithms for the extraction of the heart rate, such as Eulerian Video Magnification, Independent Component Analysis, Principal Component Analysis and Skin Detection. In the second the cardiac frequency is extracted through a mmWave radar by applying two multiple-input multiple-output (MIMO) algorithms, one based on the Fast Fourier Transform (FFT) and one on the MUltiple SIgnal Classification (MUSIC) algorithm. For both approaches, the results are compared to those obtained using more standard instruments, such as a pulse oximeter, proving the accuracy and precision of the implemented systems.
Supported by Università Politecnica delle Marche.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Alghoul, K., Alharthi, S., Al Osman, H., El Saddik, A.: Heart rate variability extraction from videos signals: ICA vs. EVM comparison. IEEE Access 5, 4711–4719 (2017)
Bolanos, M., Nazeran, H., Haltiwanger, E.: Comparison of heart rate variability signal features derived from electrocardiography and photoplethysmography in healthy individuals. In: 2006 International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 4289–4294 (2006)
Ciattaglia, G., Senigagliesi, L., De Santis, A., Ricciuti, M.: Contactless measurement of physiological parameters. In: 2019 IEEE 9th International Conference on Consumer Electronics (ICCE-Berlin), pp. 22–26, September 2019. https://doi.org/10.1109/ICCE-Berlin47944.2019.8966140
De Ponte Müller, F.: Survey on ranging sensors and cooperative techniques for relative positioning of vehicles. Sensor 17, 271 (2017)
Ding, L., Ali, M., Patole, S., Dabak, A.: Vibration parameter estimation using FMCW radar. In: 2016 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), pp. 2224–2228, March 2016. https://doi.org/10.1109/ICASSP.2016.7472072
Fishler, E., Haimovich, A., Blum, R., Chizhik, D., Cimini, L., Valenzuela, R.: MIMO radar: an idea whose time has come. In: Proceedings of the 2004 IEEE Radar Conference (IEEE Cat. No.04CH37509), pp. 71–78, April 2004. https://doi.org/10.1109/NRC.2004.1316398
Fletcher, R.R., Chamberlain, D., Paggi, N., Deng, X.: Implementation of smart phone video plethysmography and dependence on lighting parameters. In: 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 3747–3750 (2015)
Fouad, R.M., Omer, O.A., Aly, M.H.: Optimizing remote photoplethysmography using adaptive skin segmentation for real-time heart rate monitoring. IEEE Access 7, 76513–76528 (2019)
Gambi, E., et al.: Heart rate detection using Microsoft Kinect: validation and comparison to wearable devices. Sensors 17(8), 1776 (2017)
Instruments, T.: AWR 1843 single-chip 76-GHz to 81-GHz automotive radar sensor evaluation module (2019). http://www.ti.com/tool/AWR1843BOOST
Jian, L., Stoica, P.: MIMO Radar Signal Processing, 1st edn. Wiley-IEEE Press (2009)
Lee, H., Kim, B.H., Park, J.K., Yook, J.G.: A novel vital-sign sensing algorithm for multiple subjects based on 24-GHz FMCW doppler radar. Remote Sens. 11, 1237 (2019)
Lewandowska, M., Rumiński, J., Kocejko, T., Nowak, J.: Measuring pulse rate with a webcam – a non-contact method for evaluating cardiac activity. In: 2011 Federated Conference on Computer Science and Information Systems (FedCSIS), pp. 405–410 (2011)
Li, X., Chen, J., Zhao, G., Pietikäinen, M.: Remote heart rate measurement from face videos under realistic situations. In: 2014 IEEE Conference on Computer Vision and Pattern Recognition, pp. 4264–4271, June 2014. https://doi.org/10.1109/CVPR.2014.543
Lin, J.C., Kiernicki, J., Kiernicki, M., Wollschlaeger, P.B.: Microwave apexcardiography. IEEE Trans. Microw. Theory Tech. 27(6), 618–620 (1979). https://doi.org/10.1109/TMTT.1979.1129682
Madhav, K.V., Ram, M.R., Krishna, E.H., Reddy, K.N., Reddy, K.A.: Estimation of respiratory rate from principal components of photoplethysmographic signals. In: 2010 IEEE EMBS Conference on Biomedical Engineering and Sciences (IECBES), pp. 311–314 (2010)
Motin, M.A., Karmakar, C.K., Palaniswami, M.: Ensemble empirical mode decomposition with principal component analysis: a novel approach for extracting respiratory rate and heart rate from photoplethysmographic signal. IEEE J. Biomed. Health Inform. 22(3), 766–774 (2018)
Muñoz-Ferreras, J., Wang, J., Peng, Z., Li, C., Gómez-García, R.: FMCW-radar-based vital-sign monitoring of multiple patients. In: 2019 IEEE MTT-S International Microwave Biomedical Conference (IMBioC), vol. 1, pp. 1–3, May 2019. https://doi.org/10.1109/IMBIOC.2019.8777845
Peng, R.C., Zhou, X.L., Lin, W.H., Zhang, Y.T.: Extraction of heart rate variability from smartphone photoplethysmograms. Comput. Math. Methods Med. 2015 (2015)
Pisa, S., Pittella, E., Piuzzi, E.: A survey of radar systems for medical applications. IEEE Aerosp. Electron. Syst. Mag. 31(11), 64–81 (2016)
Poh, M., McDuff, D.J., Picard, R.W.: Advancements in noncontact, multiparameter physiological measurements using a webcam. IEEE Trans. Biomed. Eng. 58(1), 7–11 (2011)
Ram, M.R., Madhav, K.V., Krishna, E.H., Reddy, K.N., Reddy, K.A.: Use of multi-scale principal component analysis for motion artifact reduction of PPG signals. In: 2011 IEEE Recent Advances in Intelligent Computational Systems, pp. 425–430 (2011)
Ren, L., Wang, H., Naishadham, K., Kilic, O., Fathy, A.E.: Phase-based methods for heart rate detection using UWB impulse doppler radar. IEEE Trans. Microw. Theory Tech. 64(10), 3319–3331 (2016). https://doi.org/10.1109/TMTT.2016.2597824
Ricciuti, M., Ciattaglia, G., De Santis, A., Gambi, E., Senigagliesi, L.: Contactless heart rate measurements using RGB-camera and radar. In: ICT4AWE, pp. 121–129 (2020)
Rumiński, J.: Reliability of pulse measurements in videoplethysmography. Metrol. Measur. Syst. 23(3) (2016)
Secerbegovic, A., Bergsland, J., Halvorsen, P.S., Suljanovic, N., Mujcic, A., Balasingham, I.: Blood pressure estimation using video plethysmography. In: 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI), pp. 461–464 (2016)
Wang, S., Pohl, A., Jaeschke, T., Czaplik, M., Köny, M., Leonhardt, S., Pohl, N.: A novel ultra-wideband 80 GHz FMCW radar system for contactless monitoring of vital signs. In: 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 4978–4981, August 2015. https://doi.org/10.1109/EMBC.2015.7319509
Wang, Y., Liu, Q., Fathy, A.E.: CW and pulse-doppler radar processing based on FPGA for human sensing applications. IEEE Trans. Geosci. Remote Sens. 51(5), 3097–3107 (2013). https://doi.org/10.1109/TGRS.2012.2217975
Wang, Y., Wang, W., Zhou, M., Ren, A., Tian, Z.: Remote monitoring of human vital signs based on 77-GHz mm-wave FMCW radar. Sensors 20(10), 2999 (2020)
Wu, H.Y., Rubinstein, M., Shih, E., Guttag, J., Durand, F., Freeman, W.: Eulerian video magnification for revealing subtle changes in the world. ACM Trans. Graph. 31(4), 1–8 (2012)
Xiong, Y., Peng, Z., Xing, G., Zhang, W., Meng, G.: Accurate and robust displacement measurement for FMCW radar vibration monitoring. IEEE Sens. J. 18(3), 1131–1139 (2018). https://doi.org/10.1109/JSEN.2017.2778294
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 Springer Nature Switzerland AG
About this paper
Cite this paper
Senigagliesi, L., Ricciuti, M., Ciattaglia, G., De Santis, A., Gambi, E. (2021). Comparison of Video and Radar Contactless Heart Rate Measurements. In: Ziefle, M., Guldemond, N., Maciaszek, L.A. (eds) Information and Communication Technologies for Ageing Well and e-Health. ICT4AWE 2020. Communications in Computer and Information Science, vol 1387. Springer, Cham. https://doi.org/10.1007/978-3-030-70807-8_6
Download citation
DOI: https://doi.org/10.1007/978-3-030-70807-8_6
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-70806-1
Online ISBN: 978-3-030-70807-8
eBook Packages: Computer ScienceComputer Science (R0)