Abstract
This study presents a two-dimensional distribution table of Chinese head and face dimensions related to the design of respiratory protective devices. The two-dimensional distribution table is set up according to the coverage rate of head width shape length of adult men (18–60 years old) and adult women (18–60 years old). The head width was graded by 5 mm, and the morphological surface length was graded by 5 mm. In use, it can be merged reasonably according to the actual needs, calculate the coverage rate and set the model.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
CEN EN 149:2001 A1: 2009 requirements, testing and marking of filter semi masks for respiratory protection devices to prevent particulate matter (2001)
CEN EN 136:1998 requirements, testing and marking of complete respirator masks (1998)
CEN EN 143: 2000 requirements, testing and marking of particulate filters for respiratory protection devices (2000)
NIOSH, 42 CFR: 1995 Part 84: respiratory protective devices (1995)
ISO/TS 16976–2: 2010 human factors of respiratory protective equipment (2010)
ISO 16900–5: 2016 test methods and test equipment for respiratory protective devices ventilator, metabolic simulator, RPD headform and trunk model, tools and verification tools (2016)
GB 2626–2019: Respiratory protection self-priming filter type anti particulate matter respirator (2019)
GB/T 38228–2019: Respiratory protection Self-contained closed-circuit oxygen escape respirator (2019)
GB 2890–2009: Respiratory protection self-priming filter type gas mask (2009)
GB 6220–2009: Respiratory protection long tube respirator (2009)
GB/T 2428–1998: Adult head and face size (1998)
Acknowledgments
This work is supported by the National Key R&D Program of China (2017YFF0206602) and China National Institute of Standardization through the “special funds for the basic R&D undertakings by welfare research institutions”(project number 522018Y-5984).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Ran, L., Zhao, C., Zhang, X., Liu, T., Zhao, H. (2021). Size of Chinese Head and Face Related to Respiratory Protective Device Design. In: Rebelo, F. (eds) Advances in Ergonomics in Design. AHFE 2021. Lecture Notes in Networks and Systems, vol 261. Springer, Cham. https://doi.org/10.1007/978-3-030-79760-7_82
Download citation
DOI: https://doi.org/10.1007/978-3-030-79760-7_82
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-79759-1
Online ISBN: 978-3-030-79760-7
eBook Packages: EngineeringEngineering (R0)