Abstract
Aiming at the problem of low accuracy of industrial robot hand-eye calibration, a robot hand-eye calibration method based on an intermediate measurement system is proposed. The checkerboard calibration board with the marker points pasted is photographed by the camera, and the coordinates of the marker points in the checkerboard calibration board coordinate system are calculated according to the principle of cross-ratio invariance, and the coordinate system matrix between the C-Track optical dynamic tracking system and the industrial robot is established. The transformation relationship finally obtains the closed-loop coordinate system matrix transformation equation with the marker point, the checkerboard calibration board and the C-Track optical dynamic tracking system as the intermediate measurement system, thereby avoiding the introduction of the mobile industrial robot manipulator in the traditional hand-eye calibration process Kinematic error. The experimental results show that the translation error in the hand-eye relationship matrix is 0.6 mm, and the rotation error is 0.3°. Compared with the traditional hand-eye calibration method, this method improves the accuracy of hand-eye calibration, simplifies the hand-eye calibration process, and meets the needs of actual processing and production.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Cao, T.Y., Cai, H.Y., Fang, D.M., Liu, C.: Robot vision system for keyframe global map establishment and robot localization based on graphic content matching. Opt. Precis. Eng. 25(08), 2221–2232 (2017)
Lin, Y.M., Lv, N.G., Lou, X.P., Dong, M.L.: Robot vison system for 3D reconstruction in low texture environment. Opt. Precis. Eng. 23(02), 540–549 (2015)
Andreff, N., Horaud, R., Espiau, B.: Robot hand-eye calibration using structure-from-motion. Int. J. Robot. Res. 20(3), 228–248 (2001)
Malm, H., Heyden, A.: A new approach to hand-eye calibration. In: 15th International Conference on, Pattern Recognition (2000)
Yang, S.R., Yin, S.B., Ren, Y.J., Zhu, J.G., Ye, S.H.: Improvement of calibration method for robotic flexible visual measurement systems. Opt. Precis. Eng. 22(12), 3239–3246 (2014)
Tsai, R.Y., Lenz, R.K.: A new technique for fully autonomous and efficient 3D robotics hand/eye calibration. Robot. Autom. 5(3), 345–358 (1989)
Zhang, T., Ye, J.Y., Liu, X.G.: Weighted hand-eye calibration algorithm for robot grinding. J. Mech. Eng. 54(17), 142–148 (2018)
Heller, J., Havlena, M., Pajdla, T.: A branch-and-bound algorithm for globally optimal hand-eye calibration. In: 2012 IEEE Conference on Computer Vision and Pattern Recognition (CVPR). IEEE (2012)
Li, W., Lv, N.G., Dong, M.L., Lou, X.P.: Simultaneous robot-world/hand-eye calibration dual quaternion. Robot 40(03), 301–308 (2018)
Chou, J.C.K., Kamel, M.: Finding the position and orientation of a sensor on a robot manipulator using quaternions. Int. J. Robot. Res. 10(3), 240–254 (1991)
Hu, J.-S., Chang, Y.-J.: Automatic calibration of hand–eye–workspace and camera using hand-mounted line laser. IEEE/ASME Trans. Mechatron. 18(6), 1778–1786 (2013)
Chen, T.F., Wang, Y., Chen, Y.Q., Wu, X., Ma, Z.: An online hand-eye calibration approach based on cascaded filter. J. Southeast Univ. 43(S1), 138–142 (2013)
Wang, J.C., Wang, T.M., Yang, Y., Hu, L.: Robot hand-eye calibration using unscented Kalman filtering. Robot 33(05), 621–627 (2011)
Park, Y., Choi, Y., Seo, Y.: Globally optimal camera-and-rotation-sensor calibration with a branch-and-bound algorithm. Appl. Opt. 56(12), 3462 (2017)
Bi, D.X., Wang, X.L., Liu, Z.F., Wang, X.M.: New method for robot tool and camera pose calibration. Chin. J. Sci. Instrum. 40(01), 101–108 (2019)
Liu, C.J., Duan, Y., Wang, Y., Ye, S.H.: Study on the field calibration technology of robot flexible coordinate measurement system. J. Mech. Eng. 46(18), 1–6 (2010)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 Springer Nature Switzerland AG
About this paper
Cite this paper
Zhang, Q., Tian, W., Hu, J., Li, P., Wu, C. (2021). Robot Hand-Eye Calibration Method Based on Intermediate Measurement System. In: Liu, XJ., Nie, Z., Yu, J., Xie, F., Song, R. (eds) Intelligent Robotics and Applications. ICIRA 2021. Lecture Notes in Computer Science(), vol 13015. Springer, Cham. https://doi.org/10.1007/978-3-030-89134-3_4
Download citation
DOI: https://doi.org/10.1007/978-3-030-89134-3_4
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-89133-6
Online ISBN: 978-3-030-89134-3
eBook Packages: Computer ScienceComputer Science (R0)