Abstract
The aim of this study is to investigate the impact of velocity fluctuations on the perfusion signal and tensor parameters in diffusion tensor cardiovascular magnetic resonance (DT-CMR) using numerical simulations. A sinusoidal velocity function with increasing amplitude and frequency and a physiological velocity function have been considered. Both velocity functions have been analyzed using two mean inter-capillary velocity distributions with varying levels of dispersion. The results of the perfusion simulations, along with previous diffusion results, have been utilized to analyse the impact of perfusion on the diffusion tensor. The findings indicated that MCSE effectively compensated the rapid velocity changes considered in the study, while PGSE was sensitive to temporal changes in velocity. STEAM was found to be more sensitive to variations in the mean-intercapillary dispersion rather than to temporal velocity fluctuations. These simulation results provide insights regarding the potential of dispersed perfusion velocity fluctuations to affect the DT-CMR signal.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Abdullah, O.M., Gomez, A.D., Merchant, S., Heidinger, M., Poelzing, S., Hsu, E.W.: Orientation dependence of microcirculation-induced diffusion signal in anisotropic tissues. Magn. Reson. Med. 76(4) (2016). https://doi.org/10.1002/mrm.25980
Alemany, I., et al.: Realistic numerical simulations of diffusion tensor CMR: the effects of perfusion and membrane permeability (2023, under review)
Alemany, I., Rose, J.N., Garnier-Brun, J., Scott, A.D., Doorly, D.J.: Random walk diffusion simulations in semi-permeable layered media with varying diffusivity. Sci. Rep. 12(1), 10759 (2022). https://doi.org/10.1038/s41598-022-14541-y
Bao, H., Li, R., He, M., Kang, D., Zhao, L.: DTI study on brain structure and cognitive function in patients with chronic mountain sickness. Sci. Rep. 9(1) (2019). https://doi.org/10.1038/s41598-019-55498-9
Barclay, K.D., Klassen, G.A., Young, C.: A method for detecting chaos in canine myocardial microcirculatory red cell flux. Microcirculation 7(5) (2000). https://doi.org/10.1111/j.1549-8719.2000.tb00132.x
Callot, V., Bennett, E., Decking, U.K., Balaban, R.S., Wen, H.: In vivo study of microcirculation in canine myocardium using the IVIM method. Magn. Reson. Med. 50(3) (2003). https://doi.org/10.1002/mrm.10568
Fibich, G., Lanir, Y., Liron, N.: Mathematical model of blood flow in a coronary capillary. Am. J. Physiol. Heart Circulatory Physiol. 265(5 34-5) (1993). https://doi.org/10.1152/ajpheart.1993.265.5.h1829
Poole, D.C., Mathieu-Costello, O.: Analysis of capillary geometry in rat subepicardium and subendocardium. Am. J. Physiol. Heart Circulatory Physiol. 259(1 28-1) (1990). https://doi.org/10.1152/ajpheart.1990.259.1.h204
Rose, J.N., Nielles-Vallespin, S., Ferreira, P.F., Firmin, D.N., Scott, A.D., Doorly, D.J.: Novel insights into in-vivo diffusion tensor cardiovascular magnetic resonance using computational modeling and a histology-based virtual microstructure. Magn. Reson. Med. 81(4) (2019). https://doi.org/10.1002/mrm.27561
Seland, J.G., Bruvold, M., Brurok, H., Jynge, P., Krane, J.: Analyzing equilibrium water exchange between myocardial tissue compartments using dynamical two-dimensional correlation experiments combined with manganese-enhanced relaxography. Magn. Reson. Med. 58(4) (2007). https://doi.org/10.1002/mrm.21323
Spinner, G.R., Stoeck, C.T., Mathez, L., von Deuster, C., Federau, C., Kozerke, S.: On probing intravoxel incoherent motion in the heart-spin-echo versus stimulated-echo DWI. Magn. Reson. Med. 82(3) (2019). https://doi.org/10.1002/mrm.27777
Stoeck, C.T., Von Deuster, C., GeneT, M., Atkinson, D., Kozerke, S.: Second-order motion-compensated spin echo diffusion tensor imaging of the human heart. Magn. Reson. Med. 75(4) (2016). https://doi.org/10.1002/mrm.25784
Acknowledgments
This work was funded by British Heart Foundation Grants RE/13/4/30184 and RG/19/1/34160.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2023 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Alemany, I., Ferreira, P.F., Nielles-Vallespin, S., Scott, A.D., Doorly, D.J. (2023). The Effect of Temporal Variations in Myocardial Perfusion on Diffusion Tensor Measurements. In: Bernard, O., Clarysse, P., Duchateau, N., Ohayon, J., Viallon, M. (eds) Functional Imaging and Modeling of the Heart. FIMH 2023. Lecture Notes in Computer Science, vol 13958. Springer, Cham. https://doi.org/10.1007/978-3-031-35302-4_6
Download citation
DOI: https://doi.org/10.1007/978-3-031-35302-4_6
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-35301-7
Online ISBN: 978-3-031-35302-4
eBook Packages: Computer ScienceComputer Science (R0)