Skip to main content

Placement of External Ventricular Drains Using an Average Model

  • Conference paper
  • First Online:
Clinical Image-Based Procedures. Translational Research in Medical Imaging (CLIP 2013)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 8361))

Included in the following conference series:

  • 768 Accesses

Abstract

Purpose: Freehand placement of external ventricular drainage is not sufficiently accurate and precise. In the absence of high quality pre-operative 3D images, we propose the use of an average model for guidance of ventricular catheters. Methods: The model was segmented to extract the ventricles and registered to five normal volunteers. The proposed method was validated by comparing the trajectory resulting from the use of the average model to the use of volunteer-specific images. Results: The distances between the target points in the model and the volunteer-specific images at the left and right foramen of Monroe were computed (Mean\(\pm \)std: 5.74\(\pm \)1.39 mm and 6.00\(\pm \)1.17 mm for the left and right side respectively). We also compared the angles between the trajectories resulting from the use of volunteer specific data and the average model and the engagement of the trajectories with the frontal horn of the ipsilateral ventricle. Conclusions: Although an average model for guidance of a surgical procedure has a number of limitations, our initial experiments show that the use of a model might provide sufficient guidance for determination of the angle of insertion. Future work will include further clinical testing and possible refinement of the model.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Toma, A.K., et al.: External ventricular drain insertion accuracy: is there a need for change in practice? Neurosurgery 65(6), 1197–1201 (2009)

    Article  MathSciNet  Google Scholar 

  2. Huyette, D.R., et al.: Accuracy of the freehand pass technique for ventriculostomy catheter placement: retrospective assessment using computer tomography scans. J. Neurosurg. 108, 88–91 (2008)

    Article  Google Scholar 

  3. Hayhurst, C., et al.: Effect of electromagnetic-navigated shunt placement on failure rates: a prospective multicenter study. J. Neurosurg. 113, 1273–1278 (2010)

    Article  Google Scholar 

  4. Levitt, M.R., et al.: Image-guided cerebrospinal fluid shunting in children: catheter accuracy and shunt survival. J. Neurosurg. Pediatr. 10, 112–117 (2012)

    Article  Google Scholar 

  5. Kestle, R.W.: Editorial: shunt malfunction. J. Neurosurg. 113, 1270–1272 (2010)

    Article  Google Scholar 

  6. Fonov, V.S., et al.: Unbiased average age-appropriate atlases for pediatric studies. NeuroImage 54(1), 313–327 (2011)

    Article  Google Scholar 

  7. Sadikot, A.F., et al.: Creation of computerized 3D MRI-integrated atlases of the human basal ganglia and thalamus. Front. Syst. Neurosci. 5, 71 (2011)

    Article  Google Scholar 

  8. Krauth, A., et al.: A mean three-dimensional atlas of the human thalamus: generation from multiple histological data. Front. Syst. Neurosci. 49(3), 2053–2062 (2010)

    Google Scholar 

  9. Fischl, B., et al.: Sequence-independent segmentation of magnetic resonance images. NeuroImage 23(Suppl. 1), S69–S84 (2004a)

    Article  Google Scholar 

  10. Pieper, S., et al.: The NA-MIC kit: ITK, VTK, pipelines, grids and 3D slicer as an open platform for the medical image computing community. Proc. IEEE Int. Symp. Biomed. Imaging: From Nano to Macro 1, 698–701 (2006)

    Google Scholar 

  11. Otsu, N.: A threshold selection method from gray-level histograms. IEEE Trans. Syst. Man Cybern. 9(1), 62–66 (1979)

    Article  MathSciNet  Google Scholar 

  12. Klein, S., et al.: Elastix: a toolbox for intensity-based medical image registration. IEEE Trans. Med. Imaging. 29, 196–205 (2010)

    Article  Google Scholar 

  13. Ibanez, L., et al.: The ITK Software Guide: The Insight Segmentation and Registration Toolkit. Kitware Inc., New York (2005)

    Google Scholar 

  14. Besl, P.J., et al.: A method for registration of 3D shapes. IEEE Trans. Pattern Anal. Mach. Intell. 14, 239–256 (1992)

    Article  Google Scholar 

  15. Rousseeuw, P.J., et al.: Robust Regression and Outlier Detection. Wiley, New York (1987)

    Book  MATH  Google Scholar 

  16. Reinertsen, I., Jakola, A., Solheim, O., Lindseth, F., Unsgård, G.: Model-guided placement of cerebral ventricular catheters. In: Barratt, D., Cotin, S., Fichtinger, G., Jannin, P., Navab, N. (eds.) IPCAI 2013. LNCS, vol. 7915, pp. 30–39. Springer, Heidelberg (2013)

    Google Scholar 

  17. Sarmento, S.A., et al.: Relationship between the coronal suture and the central lobe. Arq. Neuropsiquiatr. 66(4), 868–871 (2008)

    Article  Google Scholar 

  18. Reinertsen, I., et al.: A new system for 3D ultrasound-guided placement of cerebral ventricle catheters. IJCARS 7(1), 151–157 (2012)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to I. Reinertsen .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer International Publishing Switzerland

About this paper

Cite this paper

Reinertsen, I., Jakola, A.S., Solheim, O., Lindseth, F., Selbekk, T., Unsgaard, G. (2014). Placement of External Ventricular Drains Using an Average Model. In: Erdt, M., et al. Clinical Image-Based Procedures. Translational Research in Medical Imaging. CLIP 2013. Lecture Notes in Computer Science(), vol 8361. Springer, Cham. https://doi.org/10.1007/978-3-319-05666-1_10

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-05666-1_10

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-05665-4

  • Online ISBN: 978-3-319-05666-1

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics