Simulated microcalcifciation clusters have been used in studies performed to investigate the effect of different imaging conditions on cancer detection in breast screening. This work compares the characteristics of the simulated clusters to screen-detected calcification clusters. Using a database of 271 screen-detected cancers it was found that 67 (25%) presented radiographically as calcification clusters. The characteristics of 1215 microcalcifications from all 67 clusters and 304 microcalcifications from 30 simulated clusters were quantitatively analysed. The diameter of simulated calcifications were within the range of 99% of real calcifications. The cluster diameters of the simulated clusters were within the range of 70% of the real clusters. Our simulated calcifications had similar characteristics to real calcifications but were representative of smaller clusters which represent 17% of screen-detected cancers. Consequently, a significant change in detection of our simulated clusters due to change in imaging condition has a predictable impact on cancer detection in screening.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Warren, L.M., Mackenzie, A., Cooke, J., Given-Wilson, R.M., Wallis, M.G., Chakraborty, D.P., Dance, D.R., Bosmans, H., Young, K.C.: Effect of image quality on calcification detection in digital mammography. Med. Phys. 39, 3202–3213 (2012)
Warren, L.M., Cooke, J., Given-Wilson, R.M., Wallis, M.G., Halling-Brown, M., Mackenzie, A., Chakraborty, D.P., Bosmans, H., Dance, D.R., Young, K.C.: The effect of image processing on detection of cancers in digital mammography. AJR (in press, 2014)
Mackenzie, A., Warren, L.M., Dance, D.R., Chakraborty, D.P., Cooke, J., Halling-Brown, M.D., Looney, P.T., Wallis, M.G., Given-Wilson, R.M., Alexander, G.G., Young, K.C.: Using image simulation to test the effect of detector type on breast cancer detection. In: Proc. SPIE, vol. 9037 (in press, 2014)
Warren, L.M., Green, F.H., Shrestha, L., Mackenzie, A., Dance, D.R., Young, K.C.: Validation of simulation of calcifications for observer studies in digital mammography. Phys. Med. Biol. 58, N217-N228 (2013)
NHS Breast Screening Programme and Association of Breast Surgery, An audit of screen detected breast cancers for the year of screening April 2010 to March 2011, NHS Cancer Screening Programmes (2012)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Warren, L.M. et al. (2014). Characterisation of Screen Detected and Simulated Calcification Clusters in Digital Mammograms. In: Fujita, H., Hara, T., Muramatsu, C. (eds) Breast Imaging. IWDM 2014. Lecture Notes in Computer Science, vol 8539. Springer, Cham. https://doi.org/10.1007/978-3-319-07887-8_51
Download citation
DOI: https://doi.org/10.1007/978-3-319-07887-8_51
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-07886-1
Online ISBN: 978-3-319-07887-8
eBook Packages: Computer ScienceComputer Science (R0)