Skip to main content

Model-Based Estimation of Microscopic Anisotropy in Macroscopically Isotropic Substrates Using Diffusion MRI

  • Conference paper
  • First Online:
Book cover Information Processing in Medical Imaging (IPMI 2015)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 9123))

Included in the following conference series:

Abstract

Non-invasive estimation of cell size and shape is a key challenge in diffusion MRI. Changes in cell size and shape discriminate functional areas in the brain and can highlight different degrees of malignancy in cancer tumours. Consequently various methods have emerged recently that aim to measure the microscopic anisotropy of porous media such as biological tissue and aim to reflect pore eccentricity, the simplest shape feature. However, current methods assume a substrate of identical pores, and are strongly influenced by non-trivial size distribution. This paper presents a model-based approach that provides estimates of pore size and shape from diffusion MRI data. The technique uses a geometric model of randomly oriented finite cylinders with gamma distributed radii. We use Monte Carlo simulation to generate synthetic data in substrates consisting of randomly oriented cuboids with various size distributions and eccentricities. We compare the sensitivity of single and double pulsed field gradient (sPFG and dPFG) sequences to the size distribution and eccentricity and further compare different protocols of dPFG sequences with parallel and/or perpendicular pairs of gradients. The key result demonstrates that this model-based approach can provide features of pore shape (specifically eccentricity) that are independent of the size distribution unlike previous attempts to characterise microscopic anisotropy. We show further that explicitly accounting for size distribution is necessary for accurate estimates of average size and eccentricity, and a model that assumes a single size fails to recover the ground truth values. We find the most accurate parameter estimates for dPFG sequences with mixed parallel and perpendicular gradients, nevertheless all other sequences, including sPFG, show sensitivity as well.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Panagiotaki, E., Walker-Samuel, S., Siow, B., Johnson, S.P., Rajkumar, V., Pedley, R.B., Lythgoe, M.F., Alexander, D.C.: Noninvasive quantification of solid tumor microstructure using verdict MRI. Cancer Res. 74, 1902–1912 (2014)

    Article  Google Scholar 

  2. Savadiev, P., Campbell, J.S.W., Descoteaux, M., Deriche, R., Pike, G.B., Siddiqi, K.: Labeling of ambiguous subvoxel fibre bundle configurations in high angular resolution diffusion MRI. NeuroImage 41, 58–68 (2008)

    Article  Google Scholar 

  3. Nilsson, M., Latt, J., Stahlberg, F., van Westen, D., Hagslätt, H.: The importance of axonal undulation in diffusion MR measurements: a monte carlo simulation study. NMR Biomed. 25, 795–805 (2012)

    Article  Google Scholar 

  4. Kleinnijenhuis, M., Zerbi, V., Küsters, B., Slump, C.H., Barth, M., van Cappellen van Walsum, A.: Layer-specific diffusion weighted imaging in human primary visual cortex in vitro. Cortex 49, 2569–2582 (2013)

    Article  Google Scholar 

  5. Novikov, M., Jensen, J.H., Helpern, J.A., Fieremans, E.: Revealing mesoscopic structural universality with diffusion. Proc. Nat. Acad. Sci. 11, 5088–5093 (2014)

    Article  Google Scholar 

  6. Assaf, Y., Blumenfeld-Katzir, T., Yovel, Y., Basser, P.J.: AxCaliber: a method for measuring axon diameter distribution from diffusion MRI. Magn. Reson. Med. 59, 1347–1354 (2008)

    Article  Google Scholar 

  7. Alexander, D.C., Hubbard, P.L., Hall, M.G., Moore, E.A., Ptito, M., Parker, G.J.M., Dyrby, T.B.: Orientationally invariant indices of axon diameter and density from diffusion MRI. NeuroImage 52, 1374–1389 (2010)

    Article  Google Scholar 

  8. Ferizi, U., Schneider, T., Panagiotaki, E., Nedjati-Gilani, G., Zhang, H., Wheeler-Kingshott, C., Alexander, D.C.: A ranking of diffusion MRI compartment models with in vivo human brain data. Magn. Reson. Med. 72, 1785–92 (2014)

    Article  Google Scholar 

  9. Cory, D.G., Garroway, A.N., Miller, J.B.: Applications of spin transport as a probe of local geometry. Polym. Prepr. 31, 149–150 (1990)

    Google Scholar 

  10. Mitra, P.P.: Multiple wave-vector extensions of the NMR pulsed-field-gradient spin-echo diffusion measurement. Phys. Rev. B 51(21), 15074–15078 (1995)

    Article  Google Scholar 

  11. Lawrenz, M., Koch, M.A., Finsterbusch, J.: A tensor model and measures of microscopic anisotropy for double-wave-vector diffusion-weighting experiments with long mixing times. J. Magn. Reson. 202, 43–56 (2010)

    Article  Google Scholar 

  12. Jespersen, S.N., Lundell, H., Sonderby, C.K., Dyrby, T.B.: Orientationally invariant metrics of apparent compartment eccentricity from double pulsed field gradient diffusion experiments. NMR Biomed. 26, 1647–1662 (2013)

    Article  Google Scholar 

  13. Lasic, S., Szczepankiewicz, F., Eriksson, S., Nilsson, M., Topgaard, D.: Microanisotropy imaging: quantification of microscopic diffusion anisotropy and orientational order parameter by diffusion MRI with magic-angle spinning of the q-vector. Front. Phys. 2 (2014)

    Google Scholar 

  14. Ozarslan, E.: Compartment shape anisotropy (CSA) revealed by double pulsed field gradient MR. J. Magn. Reson. 199, 56–67 (2009)

    Article  Google Scholar 

  15. Shemesh, N., Ozarslan, E., Basser, P.J., Cohen, Y.: Accurate noninvasive measurement of cell size and compartment shape anisotropy in yeast cells using double-pulsed field gradient MR. NMR Biomed. 25, 236–246 (2012)

    Article  Google Scholar 

  16. Zhang, H., Hubbard, P.L., Parker, G.J.M., Alexander, D.C.: Axon diameter mapping in the presence of orientation dispersion with diffusion MRI. NeuroImage 56, 1301–1315 (2011)

    Article  Google Scholar 

  17. Komlosh, M.E., Ozarslan, E., Lizak, M.J., Horkay, F., Schram, V., Shemesh, N., Cohen, Y., Basser, P.J.: Pore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom. J. Magn. Reson. 208, 128–135 (2011)

    Article  Google Scholar 

  18. Hall, M., Alexander, D.C.: Convergence and parameter choice for Monte-Carlo simulations of diffusion MRI. IEEE Trans. Med. Imaging 28, 1354–1364 (2009)

    Article  Google Scholar 

  19. Neuman, C.H.: Spin echo of spins diffusing in a bounded medium. J. Chem. Phys. 60, 4508–4511 (1974)

    Article  Google Scholar 

  20. Assaf, Y., Freidlin, R.Z., Rohde, G.K., Basser, P.J.: New modeling and experimental framework to characterize hindered and restricted water diffusion in brain white matter. Magn. Reson. Med. 52, 965–978 (2004)

    Article  Google Scholar 

  21. Stepisnik, J.: Time-dependent self-diffusion by NMR spin echo. Phys. B 183, 343–350 (1993)

    Article  Google Scholar 

  22. Dyrby, T.B., Søgaard, L.V., Hall, M.G., Ptito, M., Alexander, D.C.: Contrast and stability of the axon diameter index from microstructure imaging with diffusion MRI. Magn. Reson. Med. 70, 711–721 (2013)

    Article  Google Scholar 

  23. Alexander, D.C.: A general framework for experiment design in diffusion MRI and its application in measuring direct tissue-microstructure features. Magn. Reson. Med. 60, 439–448 (2008)

    Article  Google Scholar 

Download references

Acknowledgements

The EPSRC support this work through the following grants: EP/G007748, EP/H046410/01, EP/K020439/1, EP/M020533/1.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Andrada Ianuş .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Ianuş, A., Drobnjak, I., Alexander, D.C. (2015). Model-Based Estimation of Microscopic Anisotropy in Macroscopically Isotropic Substrates Using Diffusion MRI. In: Ourselin, S., Alexander, D., Westin, CF., Cardoso, M. (eds) Information Processing in Medical Imaging. IPMI 2015. Lecture Notes in Computer Science(), vol 9123. Springer, Cham. https://doi.org/10.1007/978-3-319-19992-4_55

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-19992-4_55

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-19991-7

  • Online ISBN: 978-3-319-19992-4

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics