Abstract
This paper proposes a method to detect a reference frame in an ultrasound video of the carotid artery. This reference frame, usually located at the end of the diastole, is used as the location to measure several vascular biomarkers. Our approach is based on the analysis of the movement of the carotid walls in ultrasound images using an optical flow technique. A periodic movement resembling heart beat is observed in the resulting signals. The comparison of these signals with electrocardiograms validates the proposed method for detecting the reference frame.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Toubul, P., Hennerici, M., Meairs, S., Adams, H., Amarenco, P., et al.: Mannheim carotid intima-media thickness consensus (2004–2006). Cerebrovasc Dis. 23(1), 75–80 (2007). An update on behalf of the Advisory Board of the 3rd and 4th Watching the Risk Symposium, 13th and 15th European Stroke Conferences, Mannheim, Germany, 2004, and Brussels, Belgium, 2006
Johnsen, S., Mathiesen, E.: Carotid plaque compared with intima-media thickness as a predictor of coronary and cerebrovascular disease. Curr. Cardiol. Rep. 11(1), 21–27 (2009)
Polak, J., Meisner, A., Pencina, M., Wolf, P., D’agostino, R.: Variations in common carotid artery intima-media thickness during the cardiac cycle: implications for cardiovascular risk assessment. J. Am. Soc. Echocardiogr. 25(9), 1023–1028 (2012)
Menees, S., Zhang, D., Le, J., Chen, J., Raghuveer, G.: Variations in carotid artery intima-media thickness during the cardiac cycle in children. J. Am. Soc. Echocardiogr. 23(1), 58–63 (2010)
Molinari, F., Zeng, G., Suri, J.: A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound. Comput. Methods Programs Biomed. 100(3), 201–221 (2010)
Rocha, R., Campilho, A., Silva, J., Azevedo, E., Santos, R.: Segmentation of the carotid intima-media region in B-mode ultrasound images. Image Vis. Comput. 28, 614–625 (2010)
Rocha, R., Silva, J., Campilho, A.: Automatic segmentation of carotid B-mode images using fuzzy classification. Med. Biol. Eng. Comput. 50, 533–545 (2012)
Lucas, B., Kanade, T.: An iterative image registration technique with an application to stereo vision. In: Proceedings of the International Joint Conference on Artificial Intelligence, pp. 674–679 (1981)
Gastounioti, A., Golemati, S., Stoitsis, J., Nikita, K.: Comparison of Kalman-filter-based approaches for block matching in arterial wall motion analysis from B-mode ultrasound. Meas. Sci. Technol. 22, 114008–17 (2011)
Gastounioti, A., Golemati, S., Stoitsis, J., Nikita, K.: Carotid artery wall motion analysis from B-mode ultrasound using adaptive block matching: in silico evaluation and in vivo application. Phys. Med. Biol. 58, 8647–8661 (2013)
Golemati, S., Stoitsis, J., Gastounioti, A., Dimopoulos, A., Koropouli, V., Nikita, K.: Comparison of block matching and differential methods for motion analysis of the carotid artery wall from ultrasound images. IEEE Trans. Inf. Technol. Biomed. 16(5), 852–858 (2012)
Swillens, A., Segers, P., Torp, H., Lvstakken, L.: Two-dimensional blood velocity estimation with ultrasound: speckle tracking versus crossed-beam vector doppler based on flow simulations in a carotid bifurcation model. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57(2), 327–339 (2010)
Canny, J.: A computational approach to edge detection. IEEE Trans. Pattern Anal. Mach. Intell. PAMI 8(6), 679–698 (1986)
Rouco, J., Campilho, A.: Robust common carotid artery lumen detection in B-mode ultrasound images using local phase symmetry. In: International Conference on Acoustics, Speech and Signal Processing, pp. 929–933 (2013)
Bland, J., Altman, D.: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327, 307–310 (1986)
Wikstrand, J.: Methodological considerations of ultrasound measurement of carotid artery intima-media thickness and lumen diameter. Clin. Physiol. Imaging 27, 341–345 (2007)
Acknowledgements
T. Araújo and G. Aresta equally contributed to this work. This work is financied by the FCT - Fundação para a Ciência e Tecnologia (Portuguese Foundation for Science and Technology) within the project UID/EEA/50014/2013 and the grant contract SFRH/BPD/79154/2011.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer International Publishing Switzerland
About this paper
Cite this paper
Araújo, T., Aresta, G., Rouco, J., Ferreira, C., Azevedo, E., Campilho, A. (2015). Optical Flow Based Approach for Automatic Cardiac Cycle Estimation in Ultrasound Images of the Carotid. In: Kamel, M., Campilho, A. (eds) Image Analysis and Recognition. ICIAR 2015. Lecture Notes in Computer Science(), vol 9164. Springer, Cham. https://doi.org/10.1007/978-3-319-20801-5_39
Download citation
DOI: https://doi.org/10.1007/978-3-319-20801-5_39
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-20800-8
Online ISBN: 978-3-319-20801-5
eBook Packages: Computer ScienceComputer Science (R0)