Skip to main content

High Performance Dynamic Threshold Calibration for RR Interval Detection in a QRS Complex Using a Parallel Programing

  • Conference paper
  • First Online:
Mobile Networks for Biometric Data Analysis

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 392))

  • 608 Accesses

Abstract

These days computer analysis of ECG (Electrocardiograms) signals is common. There are many real-time QRS recognition algorithms; one of these algorithms is Pan-Tompkins Algorithm. Which the Pan-Tompkins Algorithm can detect QRS complexes of ECG signals. The proposed algorithm is analysed the data stream of the heartbeat based on the digital analysis of the amplitude, the bandwidth, and the slope. In addition to that, the stress algorithm compares whether the current heartbeat is similar or different to the last heartbeat after detecting the ECG signals. This algorithm determines the stress detection for the patient on the real-time. In order to implement the new algorithm with higher performance, the parallel programming language CUDA is used. The algorithm determines stress at the same time by determining the RR interval. The algorithm uses a different function as beat detector and a beat classifier of stress.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Pan J, Tompkins WJ (1985) A real-time QRS detection algorithm. IEEE Trans Biomed Eng 3:230–236

    Article  Google Scholar 

  2. Bakker J, Pechenizkiy M, Sidorova N (2011) What’s your current stress level? Detection of stress patterns from GSR sensor data. In: IEEE 11th international conference on data mining workshops (ICDMW). IEEE

    Google Scholar 

  3. Glanz K, Schwartz M (2008) Stress, coping, and health behavior. Health behavior and health education: theory, research, and practice, pp 211–236

    Google Scholar 

  4. Lascu, M, Dan L (2007) LabVIEW event detection using Pan-Tompkins algorithm. In: Proceedings of the 7th WSEAS international conference on signal, speech and image processing, Beijing, China

    Google Scholar 

  5. Elgendi M Fast T-wave detection with annotation of P and T waves in the MIT-BIH arrhythmia database

    Google Scholar 

  6. Elgendi M et al (2008) A robust QRS complex detection algorithm using dynamic thresholds. In: International symposium on computer science and its applications, CSA’08. IEEE (2008)

    Google Scholar 

  7. Hamilton P (2002) Open source ECG analysis. Computers in cardiology. IEEE

    Google Scholar 

  8. MIT-BIH Arrhythmia Database www.physionet.org

  9. Scherz WD, Seepold R (2014) Physiologic parameter calculation supporting local and telemetric analysis. In: 6th European conference of the international federation for medical and biological engineering (MBEC)

    Google Scholar 

  10. Martínez Madrid N, Martínez Fernández J, Seepold R, Augusto JC (2013) Ambient assisted living (AAL) and smart homes. Autonomous Sensor Networks, Springer Series on Chemical Sensors and Biosensors, vol 13. ISSN: 1612-7617, pp 39–71

    Google Scholar 

  11. Pavlatos C et al (2005) Hardware implementation of Pan & Tompkins QRS detection algorithm. Proceedings of the EMBEC’05 conference

    Google Scholar 

  12. Okada M (1979) A digital filter for the QRS detection complex. IEEE Trans Biomed Eng 26:700–703

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mohammed Rajab .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer International Publishing Switzerland

About this paper

Cite this paper

Rajab, M., Seepold, R. (2016). High Performance Dynamic Threshold Calibration for RR Interval Detection in a QRS Complex Using a Parallel Programing. In: Conti, M., Martínez Madrid, N., Seepold, R., Orcioni, S. (eds) Mobile Networks for Biometric Data Analysis. Lecture Notes in Electrical Engineering, vol 392. Springer, Cham. https://doi.org/10.1007/978-3-319-39700-9_16

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-39700-9_16

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-39698-9

  • Online ISBN: 978-3-319-39700-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics