Abstract
The person’s heart rate is an important indicator of their health status. A heart rate that is too high or too low could be a sign of several different diseases, such as a heart disorder, obesity, asthma, or many others. Many devices require users to wear the device on their chest or place a finger on the device. The approach presented in this paper describes the principle and implementation of a heart rate monitoring device, which is able to detect the heart rate with high precision with the sensor integrated in a wristband. One method to measure the heart rate is the photoplethysmogram technique. This method measures the change of blood volume through the absorption or reflection of light. A light emitting diode (LED) shines through a thin amount of tissue. A photo-diode registers the intensity of light that traverses the tissue or is reflected by the tissue. Since blood changes its volume with each heartbeat, the photo-diode detects more or less light from the LED. The device is able to measure the heart rate with a high precision, it has low performance and hardware requirements, and it allows an implementation with small micro-controllers.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Notes
References
MartĂnez Fernández J, Augusto JC, Trombino G, Seepold R, MartĂnez Madrid N (2013) Self-aware trader: a new approach to safer trading, J Universal Comput Sc, 19(15): 2292–2319, ISSN: 0948-695X
MartĂnez J, Augusto JC, Seepold R,Madrid NM (2012) A sensor technology survey for a stress aware trading process, IEEE Trans Systems, Man and Cybernetics—Part C: Appl and Rev, ISSN: 1094-6977
Crowley OV, McKinley PS, Burg MM, Schwartz JE, Ryff CD, Weinstein M et al (2011) The interactive effect of change in perceived stress and trait anxiety on vagal recovery from cognitive challenge. Int J Psychophysiol 82:225–232
Pan RL, Li JK (2007) A noninvasive parametric evaluation of stress effects on global cardiovascular function. Cardiovasc Eng 7:74–80
Melillo P, Bracale M, Pecchia L (2011) Nonlinear Heart Rate Variability features for real-life stress detection. Case study: students under stress due to university examination. BioMedical Eng OnLine 10:1–13
Hjortskov N, Rissén D, Blangsted A, Fallentin N, Lundberg U, Søgaard K (2004) The effect of mental stress on heart rate variability and blood pressure during computer work. Eur J Appl Physiol 92:84–89
Chandola T, Heraclides A, Kumari M (2010) Psychophysiological biomarkers of workplace stressors. Neurosci Biobehav Rev 35:51–57
Scherz WD, Seepold R (2015) Physiologic parameter calculation supporting local and telemetric analysis. In: 6th Euro-pean Conference of the International Federation for Medical and Biological Engineering, International Federation for Medical and Biological Engineering (IFMBE), 45, ISSN 1680-0737
Einthoven W (1908) Weiteres über das Elektrokardiogram. Pflüger Arch. ges. Physiol, 517–548
Kohler B-U, Hennig C, Orglmeister R (2002) The principles of software QRS detection. IEEE Eng Med Biol Mag 21(1):42–57
Polar RS800cx, Available: http://www.polar.com/en/products/maximize_performance/running_multisport/RS800CX, Cited Sept 2014
Firstbeat Stress Monitoring, Available: http://www.firstbeattechnologies.com/index.php?page=3&sub_page=19&sub_page_2=93, Cited Sept 2014
Stresseraser, Available: http://www.stresseraser-uk.com, Cited Sept 2014
Mind Media, NeXus-10 MKII, http://www.mindmedia.info, Cited Sept 2014
TSL2561, Available: https://learn.adafruit.com/tsl2561/overview, Cited May 2014
Steven W, Smith (2014) The scientist and engineer’s guide to digital signal processing. online book 1997 Available: http://www.dspguide.com/, Cited Jul 2014
Amidror I (2013) mastering the discrete fourier transform in one, two or several dimensions—pitfalls and artifacts. Springer
Smith JO (2014) Mathematics of the discrete fourier transform (DFT) with audio applications, online book 2007 Available: https://ccrma.stanford.edu/~jos/mdft/, Cited May 2014
Rusch TL, Sankar R, Scharf JE (1996) Signal processing methods for pulse oximetry. Comput Biol Med 26:143–159
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this paper
Cite this paper
Gansloser, J., Seepold, R. (2016). Development of an Algorithm and a Sensor to Monitor the Heart Rate by Volumetric Measurement Techniques. In: Conti, M., MartĂnez Madrid, N., Seepold, R., Orcioni, S. (eds) Mobile Networks for Biometric Data Analysis. Lecture Notes in Electrical Engineering, vol 392. Springer, Cham. https://doi.org/10.1007/978-3-319-39700-9_7
Download citation
DOI: https://doi.org/10.1007/978-3-319-39700-9_7
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-39698-9
Online ISBN: 978-3-319-39700-9
eBook Packages: EngineeringEngineering (R0)