Abstract
We evaluated the diagnostic performance of a novel image processing technique of synthetic MMG (SMMG) as 2D-like visualization approach with and without DBT slice images (DBT) compared with that of 2D MMG (MMG) alone. With one-view MMG and DBT, the radiation doses, utilizing the ACR phantom 156, were 1.20 mGy and 1.80 mGy. The number of the cases was 108. MMG, SMMG, and DBT slice images were evaluated independently by 4 readers utilizing ROC analysis and diagnostic performance. SMMG plus DBT demonstrated higher area under the curve (AUC) and superior diagnostic accuracy with sensitivity, specificity, and NPV compared with SMMG and MMG alone (p < 0.05). In addition, a 40 % decrease of radiation dose with SMMG plus DBT compared with MMG plus DBT as the current setting will enable us to apply a two-view SMMG plus DBT in breast cancer screening instead of MMG.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Abdurahman, S., Dennerlein, F., Jerebko, A., Fieselmann, A., Mertelmeier, T.: Optimizing high resolution reconstruction in digital breast tomosynthesis using filtered back projection. In: Fujita, H., Hara, T., Muramatsu, C. (eds.) IWDM 2014. LNCS, vol. 8539, pp. 520–527. Springer, Heidelberg (2014)
Skaane, P., Bandos, A.I., Gullien, R., et al.: Comparison of digital mammography alone and digital mammography plus tomosynthesis in a populationbased screening program. Radiology 267(1), 47–56 (2013)
Bernardi, D., Caumo, F., Macaskill, P., et al.: Effect of integrating 3D-mammography (digital breast tomosynthesis) with 2D-mammography on radiologists’ true-positive and false-positive detection in a population breast screening trial. Eur. J. Cancer 50(7), 1232–1238 (2014)
Lång, K., Andersson, I., Rosso, A., et al.: Performance of one-view breast tomosynthesis as a stand-alone breast cancer screening modality: results from the Malmö Breast Tomosynthesis Screening Trial, a population-based study. Eur. Radiol. 26, 184–190 (2016)
Gur, D., Zuley, M.L., Anello, M.I., et al.: Dose reduction in digital breast tomosynthesis (DBT) screening using synthetically reconstructed projection images: an observer performance study. Acad. Radiol. 19(2), 166–171 (2012)
Zuley, M.L., Guo, B., Catullo, V.J., et al.: Comparison of two-dimensional synthesized mammograms versus original digital mammograms alone and in combination with tomosynthesis images. Radiology 271(3), 664–671 (2014)
Van, S.G., Mann, R., Imhof-tas, M., et al.: Generating synthetic mammograms from reconstructed tomosynthesis volumes. IEEE Trans. Med. Imaging 32(12), 2322–2331 (2013)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this paper
Cite this paper
Uchiyama, N. et al. (2016). Diagnostic Usefulness of Synthetic MMG (SMMG) with DBT (Digital Breast Tomosynthesis) for Clinical Setting in Breast Cancer Screening. In: Tingberg, A., Lång, K., Timberg, P. (eds) Breast Imaging. IWDM 2016. Lecture Notes in Computer Science(), vol 9699. Springer, Cham. https://doi.org/10.1007/978-3-319-41546-8_8
Download citation
DOI: https://doi.org/10.1007/978-3-319-41546-8_8
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-41545-1
Online ISBN: 978-3-319-41546-8
eBook Packages: Computer ScienceComputer Science (R0)