Abstract
The paper discusses rigid registration of a 3D volume to 2D projections based on Mutual-Information similarity measures. The experiments we conducted are similar to those of Zoellei. However, in order to obtain a stopping criterion we use the Resilient Backpropagation as optimizer. Performing the registration on artificial images we obtain a speedup of approx. a factor of 10. We applied the matching approach to calibrate C-arm positions and found lateral movements of the detector of 0.5-1 mm in a given set of projections.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Weese, J., Buzug, T.M., et al.: An approach to 2D/3D Registration of a Vertebra in 2D X-ray Fluoroscopies with 3D CT images. CVRMed-MRCAS, Grenoble (1997)
Tang, T.S.Y., Ellis, R.E., Fichtinger, G.: Fiducial Registration from a Single X-rayImage; A New Technique for Fluoroscopic Guidance and Radiotherapy. In: Delp, S.L., DiGoia, A.M., Jaramaz, B. (eds.) MICCAI 2000. LNCS, vol. 1935, pp. 502–511. Springer, Heidelberg (2000)
Liu, A., Bullit, E., Pizer, S.M.: 3D/2D Registration via skeletal near projective invariance in tubular objects. In: Wells, W.M., Colchester, A.C.F., Delp, S.L. (eds.) MICCAI 1998. LNCS, vol. 1496, pp. 952–963. Springer, Heidelberg (1998)
Penney, G., Weese, J., et al.: A Comparison of Similarity Measures for Use in 2D-3D Medical Image Registration. In: Wells, W.M., Colchester, A.C.F., Delp, S.L. (eds.) MICCAI 1998. LNCS, vol. 1496, pp. 1153–1161. Springer, Heidelberg (1998)
Hipwell, J., Penney, G., et al.: 2D-3D Intensity Based Registration of DSA and MRA - A comparison of similarity measures. In: Dohi, T., Kikinis, R. (eds.) MICCAI 2002. LNCS, vol. 2489, pp. 501–508. Springer, Heidelberg (2002)
Chung, A., Wells, W., et al.: Multi-modal image registration by minimising kullback-leibler distance. In: Dohi, T., Kikinis, R. (eds.) MICCAI 2002. LNCS, vol. 2489, pp. 525–532. Springer, Heidelberg (2002)
Jonic, S., Thevenaz, P., Unser, M.: Multiresolution-based registration of a volume to a set of its projections. Swiss Federal Institute of Technology, Lausanne (2001) (?)
LaRose, D.: Iterative X-ray/CT Registration using Accelerated Volume Rendering. PhD-Thesis Carnegie Mellon University (2001)
Rohlfing, T., Beier, J., et al.: Multimodale Registrierung mit effizienten Lernverfahren für neuronale Netze. In: Lehmann, et al. (Hrsg.) Bildverarbeitung für die Medizin 1998: Algorithmen-Systeme-Anwendungen, RWTH Aachen. Springer, Heidelberg (1998)
Rohlfing, T., Russakov, D.B., et al.: An intensity-based registration algorithm for probabilistic images and its application for 2-D to 3-D registration. In: Proceedings of SPIE, vol. 4684 (2002)
Rohlfing, T., Maurer, C.R.: A Novel Image Similarity Measure for Registration if 3-D MR Images and X-Ray Projection Images. In: Dohi, T., Kikinis, R. (eds.) MICCAI 2002. LNCS, vol. 2489, pp. 469–476. Springer, Heidelberg (2002)
Viola, P.: Alignment by Maximization of Mutual Information. PhD-Thesis, Massachusetts Institute of Technology (1995)
Zoellei, L.: 2D-3D Rigid-Body Registration of X-Ray Fluoroscopy and CT Images. Masters Thesis, Massachusetts Institute of Technology (2001)
Meihe, X., Srinivasan, R., Nowinski, W.L.: A Fast Mutual Information Method forMulti-modal Registration. In: Kuba, A., Sámal, M., Todd-Pokropek, A. (eds.) IPMI 1999. LNCS, vol. 1613, pp. 466–471. Springer, Heidelberg (1999)
Feldkamp, L.A., Davis, L.C., Kress, J.W.: Practical cone-beam algorithm. J. Opt. Soc. Amer. 1(6), 612–619 (1984)
Bruck, S.: Geometriekorrektur bei der 3D-Rekonstruktion aus C-Arm-Projektionen. Masters Thesis, Universität Mannheim (2002)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2003 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Müller, U., Bruck, S., Hesser, J., Männer, R. (2003). Correction of C-Arm Projection Matrices by 3D-2D Rigid Registration of CT-Images Using Mutual Information. In: Gee, J.C., Maintz, J.B.A., Vannier, M.W. (eds) Biomedical Image Registration. WBIR 2003. Lecture Notes in Computer Science, vol 2717. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-39701-4_17
Download citation
DOI: https://doi.org/10.1007/978-3-540-39701-4_17
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-20343-8
Online ISBN: 978-3-540-39701-4
eBook Packages: Springer Book Archive