Skip to main content

Non-rigid Spatio-Temporal Alignment of 4D Cardiac MR Images

  • Conference paper
Biomedical Image Registration (WBIR 2003)

Part of the book series: Lecture Notes in Computer Science ((LNCS,volume 2717))

Included in the following conference series:

Abstract

In this paper we further develop of a 4D registration algorithm for the spatio-temporal alignment of cardiac MR image sequences.The registration algorithm has the ability not only to correct any spatial misalignment between the image sequences but also any temporal misalignment which maybe the result of differences in the cardiac cycle between subjects and differences in the temporal acquisition parameters. The algorithm uses a 4D transformation model which is separated into a spatial and a temporal component. In this approach the spatial part of transformation is composed by a global affine transformation and a local free-form deformation based on B-splines. The spatial part not only corrects spatial differences of a global nature but also local spatial differences of the cardiac shape. The temporal component uses an affine transformation which corrects the temporal misalignment caused by differences in the initial acquisition offset and length of the two cardiac cycles. The method was applied to a number of cardiac MR image sequences from healthy volunteers. The registration was qualitatively evaluated by visual inspection and quantitatively by measuring overlap of anatomical regions between the sequences. The results are compared with the results of the previously developed 4D registration method. A significant improvement in the alignment of the images is achieved by the use of free-form deformation models.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. American Heart Association. Heart and stroke statistical update (2002), http://www.americanheart.org/

  2. Perperidis, D., Rao, A., Lorenzo-Valdés, M., Mohiaddin, R., Rueckert, D.: Spatio-temporal alignment of 4D cardiac MR images. In: Magnin, I.E., Montagnat, J., Clarysse, P., Nenonen, J., Katila, T. (eds.) FIMH 2003. LNCS, vol. 2674. Springer, Heidelberg (2003)

    Chapter  Google Scholar 

  3. Mäkelä, T., Clarysse, P., Sipila, N., Pauna, O., Pham, Q.C.: A review of cardiac image registration methods. IEEE Transcactions on Medical Imaging 21(9) (2002)

    Google Scholar 

  4. Maintz, J.B.A., Viergever, M.A.: A survey of medical image registration. Medical Image Analysis 2(1), 1–37 (1998)

    Article  Google Scholar 

  5. Hill, D.L.G., Batchelor, P.G., Holden, M., Hawkes, D.J.: Medical image registration. Physics in Medical Biology 46(3), R1–R45 (2001)

    Google Scholar 

  6. Lester, H., Arridge, S.: A survery of hierarchical non-linear medical image registration. Pattern Recognition 32(1), 129–149 (1999)

    Article  Google Scholar 

  7. Manke, D., Rosch, P., Nehrke, K., Bornert, P., Dossel, O.: Model evaluation and calibration for prospective respiratory motion correction in coronaryMRangiography based on 3D image registration. IEEE Transcactions on Medical Imaging 21(9) (2002)

    Google Scholar 

  8. McLeish, K., Hill, D.L.G., Atkinson, D., Blackall, J.M., Razavi, R.: A study of the motion and deformation of the heart due to respiration. IEEE Transcactions on Medical Imaging 21(9) (2002)

    Google Scholar 

  9. Chandrashekara, R., Mohiaddin, R.H., Rueckert, D.: Analysis of myocardial motion in taggedMRimages using nonrigid image registration. In: Sonka, M., Michael Fitzpatrick, J. (eds.) Proceedings of the SPIE International Symposium on Medical Imaging, San Diego, California USA, February 24–28, pp. 1168–1179. SPIE, Bellingham (2002)

    Google Scholar 

  10. Chadrashekar, R., Rao, A., Sanchez-Ortiz, G., Mohiaddin, R., Rueckert, D.: Construction of a statistical model for cardiac motion analysis using non-rigid image registration. In: Information Processing in Medical Imaging 2003, Amleside, UK, July 20-25 (2003)

    Google Scholar 

  11. Gilardi, M.C., Rizzo, G., Savi, A., Landoni, C., Bettinardi, V., Rosseti, C., Striano, G., Fazio, F.: Correlation of SPECT and PET cardiac images by a surface matching registration technique. Computerized Medical Imaging and Graphics 22(5), 391–398 (1998)

    Article  Google Scholar 

  12. Turkington, T.G., DeGradom, T.R., Hanson, M.W., Coleman, E.R.: Alignment of dynamic cardiac PET images for correction of motion. IEEE Transaction on Nuclear Science 44(2), 235–242 (1997)

    Article  Google Scholar 

  13. Bidaut, L.M., Vallëe, J.P.: Automated registration of dynamic MR images for the quantification of myocardial perfusion. Journal Of Magnetic Resonance Imaging 13(4), 648–655 (2001)

    Article  Google Scholar 

  14. Rao, A., Sanchez-Ortiz, G.I., Chandrashekara, R., Lorenzo-Valdés, M., Mohiaddin, R., Rueckert, D.: Comparison of cardiac motion across subjects using non-rigid registration. In: Dohi, T., Kikinis, R. (eds.) MICCAI 2002. LNCS, vol. 2488, p. 722. Springer, Heidelberg (2002)

    Chapter  Google Scholar 

  15. Mazziotta, J.C., Toga, A.W., Evans, A., Fox, P., Lancaster, J.: A probabilistic atlas of the human brain:theory and rationale for its development. The international consortium for brain mapping. Neuroimage 2, 89–101 (1995)

    Article  Google Scholar 

  16. Klein, G.J., Reutter, B.W., Huesman, R.H.: Four dimensional affine registration models for respiratory-gated PET. IEEE Transactions on Nuclear Science 48(3), 756–760 (2001)

    Article  Google Scholar 

  17. Klein, G.J.: Four dimensional processing of deformable cardiac PET data. In: workshop on Mathematical Methods in Biomedical Image Analysis, Hilton Head Island, SC, June 11-12, pp. 127–134 (2000)

    Google Scholar 

  18. Klein, G.J., Huesman, R.H.: Four dimensional processing of deformable cardiac PET data. Medical Image Analysis 6(1), 29–46 (2002)

    Article  Google Scholar 

  19. Caspi, Y., Irani, M.: Spatio-temporal alignment of sequences. IEEE Transactions on Pattend Analysis and Machine Intelligence 24(11), 1409–1424 (2002)

    Article  Google Scholar 

  20. Rueckert, D., Sonoda, L.I., Hayes, C., Hill, D.L.G., Leach, M.O., Hawkes, D.J.: Nonrigid registration using free-form deformations: Application to breast MR images. IEEE Transactions on Medical Imaging 18(8), 712–721 (1999)

    Article  Google Scholar 

  21. Studholme, C., Hill, D.L.G., Hawkes, D.J.: An overlap invariant entropy measure of 3D medical image alignment. Pattern Recognition 32, 71–86 (1999)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2003 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Perperidis, D., Rao, A., Mohiaddin, R., Rueckert, D. (2003). Non-rigid Spatio-Temporal Alignment of 4D Cardiac MR Images. In: Gee, J.C., Maintz, J.B.A., Vannier, M.W. (eds) Biomedical Image Registration. WBIR 2003. Lecture Notes in Computer Science, vol 2717. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-39701-4_20

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-39701-4_20

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-20343-8

  • Online ISBN: 978-3-540-39701-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics