The performance of a wide range of digital mammography systems has been compared in terms of the dose required to achieve the image quality standards in the European guidelines at different detail sizes. This paper considers how these results relate to measurements of detector performance on these systems. The dose to meet the minimum requirements in European Guidelines was found to be strongly related to the DQE of the detector systems. Thus where a system has a relatively low DQE at high spatial frequencies (e.g. 5 cycles per mm) a relatively large dose is required to meet the minimum image quality level in European Guidelines for the smallest detail size (i.e. 0.1 mm). The systems showed a very wide range in performance.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Van Engen, R., Young, K.C., Bosmans, H., Thijssen, M.: The European Protocol for the Quality Control of the Physical and Technical Aspects of Mammography Screening. Part B: Digital Mammography. In: European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis, 4th edn., European Commission, Luxembourg (2006)
Workman, A., Castallano, I., Kulama, E., Lawinski, C.P., Marshall, N., Young, K.C.: Commissioning and Testing of Full Field Digital Mammography Systems (NHSBSP Equipment Report 0604). NHS Cancer Screening Programmes, Sheffield (2006)
IEC 62220-1-2, Determination of the detective quantum efficiency – Detectors used in mammography. International Electrotechnical Commission (2007)
Young, K.C., Cook, J.J.H., Oduko, J.M., Bosmans, H.: Comparison of Software and Hu-man Observers in Reading Images of the CDMAM Test Object to Assess Digital Mam-mography Systems. In: Proceedings of SPIE Medical Imaging, vol. 6142, 614206, pp. 1–13. SPIE Publications, Bellingham WA (2006)
Young, K.C., Cook, J.J.H., Oduko, J.M.: Automated and Human Determination of Thresh-old Contrast for Digital Mammography Systems. In: Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds.) IWDM 2006. LNCS, vol. 4046, pp. 266–272. Springer, Heidelberg (2006)
Young, K.C., Alsager, A., Oduko, J.M., Bosmans, H., Verbrugge, B., Geertse, T., Van Engen, R.: Evaluation of Software for Reading Images of the CDMAM Test Object to Assess Digital Mammography Systems. In: Proceedings of SPIE Medical Imaging, vol. 6913, 69131C, pp. 1–11. SPIE Publications, Bellingham WA (2008)
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Young, K.C., Oduko, J.M., Gundogdu, O., Alsager, A. (2008). Comparing the Performance of Digital Mammography Systems. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_101
Download citation
DOI: https://doi.org/10.1007/978-3-540-70538-3_101
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-70537-6
Online ISBN: 978-3-540-70538-3
eBook Packages: Computer ScienceComputer Science (R0)