Skip to main content

Detection of Masses in Digital Breast Tomosynthesis Mammography: Effects of the Number of Projection Views and Dose

  • Conference paper
Digital Mammography (IWDM 2008)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 5116))

Included in the following conference series:

Abstract

We are developing a computer-aided detection (CAD) system for masses on digital breast tomosynthesis mammograms (DBT). A data set of DBT from patients was collected with informed consent using a GE prototype DBT system. The system has an Rh/Rh x-ray source and a CsI/a:Si detector, and acquires 21 projection view (PV) images over a 60º arc in 3º increments. The total dose of the 21 PVs is set to be about 1.5 times of the dose of a single screen-film mammogram. In this preliminary study, the DBTs from 50 patients are reconstructed with a simultaneous algebraic reconstruction technique (SART) in two conditions: one using all 21 PVs in 3º increments and the other 11 PVs in 6º increments. The latter therefore uses a subset of the PVs and about half the dose of the former. We compared the mass detection accuracy in these two sets of DBTs using the same CAD system. The system first identifies locations of mass candidates in the DBT volume using 3D gradient field analysis. The mass candidates are then segmented by 3D region growing. Morphological, gray level, and texture features are extracted from the segmented objects. A linear discriminant analysis (LDA) classifier with stepwise feature selection is designed by leave-one-out resampling. The output of the LDA is a mass likelihood score to which a decision threshold is applied and a free-response receiver operating characteristic (FROC) curve is generated. For the DBT set reconstructed with 21 PVs, the system achieved an 80% sensitivity at an average false positive (FP) rate of 1.52 per DBT volume. For the DBT set reconstructed with 11 PVs, the FP rate was 2.38 per breast at the same sensitivity. The difference in the FROC curves for the two conditions was statistically significant (p=0.03) by alternative FROC analysis. When the subset of 14 malignant cases was analyzed, the average FP rates were 0.87 and 1.11 per DBT volume at a sensitivity of 80% for the 21-PV and 11-PV conditions, respectively. The difference in the FROC curves for this smaller subset did not achieve statistical significance.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Rafferty, E.A., Georgian-Smith, D., Kopans, D.B., Hall, D.A., Moore, R., Wu, T.: Comparison of full-field digital tomosynthesis with two view conventional film screen mammography in the prediction of lesion malignancy. Radiology 225(P), 268 (2002)

    Google Scholar 

  2. Chan, H.P., Wei, J., Sahiner, B., Rafferty, E.A., Wu, T., Ge, J., Roubidoux, M.A., Moore, R.H., Kopans, D.B., Hadjiiski, L.M., Helvie, M.A.: Computer-aided detection on digital breast tomosynthesis (DBT) mammograms - comparison of two approaches. In: RSNA Program Book 2004, p. 447 (2004)

    Google Scholar 

  3. Chan, H.-P., Wei, J., Sahiner, B., Rafferty, E.A., Wu, T., Roubidoux, M.A., Moore, R.H., Kopans, D.B., Hadjiiski, L.M., Helvie, M.A.: Computer-aided detection system for breast masses on digital tomosynthesis mammograms - preliminary experience. Radiology 237, 1075–1080 (2005)

    Article  Google Scholar 

  4. Chan, H.-P., Wei, J., Wu, T., Sahiner, B., Rafferty, E.A., Hadjiiski, L.M., Helvie, M.A., Roubidoux, M.A., Moore, R.H., Kopans, D.B.: Computer-aided detection on digital breast tomosynthesis (DBT) mammograms: Dependence on image quality of reconstruction. In: RSNA Program Book 2005, p. 269 (2005)

    Google Scholar 

  5. Chan, H.P., Wei, J., Zhang, Y., Helvie, M.A., Moore, R.H., Kopans, D., Roubidoux, M.A., Sahiner, B., Hadjiiski, L.M.: Digital breast tomosynthesis (DBT) mammography: Computer-aided mass detection by fusion of tomosynthesis and 3d mass likelihood information. In: RSNA Program Book 2006, p. 230 (2006)

    Google Scholar 

  6. Reiser, I., Nishikawa, R.M., Giger, M.L., Wu, T., Rafferty, E., Moore, R.H., Kopans, D.B.: Computerized detection of mass lesions in digital breast tomosynthesis images using two- and three dimensional radial gradient index segmentation. Technology in Cancer Research and Treatment 3, 437–441 (2004)

    Google Scholar 

  7. Reiser, I., Nishikawa, R.M., Giger, M.L., Wu, T., Rafferty, E.A., Moore, R.H., Kopans, D.B.: Computerized mass detection for digital breast tomosynthesis directly from the projection images. Medical Physics 33, 482–491 (2006)

    Article  Google Scholar 

  8. Zhang, Y., Chan, H.-P., Sahiner, B., Wei, J., Goodsitt, M.M., Hadjiiski, L.M., Ge, J., Zhou, C.: A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis. Medical Physics 33, 3781–3795 (2006)

    Article  Google Scholar 

  9. Chakraborty, D.P., Winter, L.H.L.: Free-response methodology: Alternate analysis and a new observer-performance experiment. Radiology 174, 873–881 (1990)

    Google Scholar 

  10. Zhang, Y., Chan, H.P., Goodsitt, M.M., Schmitz, A., Eberhard, J., Claus, B.: Investigation of different PV distributions in digital tomosynthesis mammography (DBT). In: Proceedings of IWDM-2008 (2008) (in press)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Elizabeth A. Krupinski

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Chan, HP., Wei, J., Zhang, Y., Sahiner, B., Hadjiiski, L., Helvie, M.A. (2008). Detection of Masses in Digital Breast Tomosynthesis Mammography: Effects of the Number of Projection Views and Dose. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_39

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-70538-3_39

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-70537-6

  • Online ISBN: 978-3-540-70538-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics