Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. Retrospective ECG gating techniques have already been adapted from clinical cardiac CT that allow 3D reconstruction using retrospectively gated projection images of a multi-sweep C-arm CT scan according to the desired cardiac phase. However, it is known that retrospective gating of projection data does not provide an optimal signal-to-noise-ratio (SNR) since the measured projection data is only partially considered during the reconstruction. In this work we introduce a new reconstruction technique for cardiac C-arm CT that provides increased SNR by including additional corrected and resampled filtered back-projections (FBP) from temporal windows outside of the targeted reconstruction phase. We take advantage of several motion corrected FDK-like reconstructions of the subject to increase SNR. In the presented results, using in vivo data from an animal model, the SNR could be increased by approximately 30 percent.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Feldkamp LA, Davies LC, Kress JW. Practical cone-beam algorithm. J Opt Soc Am A1 1984:612–619.
Lauritsch G, Boese J, Wigström L, Kemeth H, Fahrig R. Towards Cardiac C-arm Computed Tomography. IEEE Trans Med Imaging 2006;25:922–934.
Li T, Schreibmann E, Thorndyke B, Tillman G, Boyer A, Koong A, et al. Radiation dose reduction in four-dimensional computed tomography. Med Phys 2005;32(12):3650–3660.
Prümmer M, Wigström L, Hornegger J, Boese J, Lauritsch G, Strobel N, et al. Cardiac C-Arm CT: Efficient motion correction for 4D-FBP. Procs IEEE Medical Imaging Conference, San Diego, 2006, accepted for publication.
Modersitzki J. Numerical Methods for Image Registration. Oxford University Press, 2004.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Prümmer, M., Wigström, L., Fahrig, R., Lauritsch, G., Hornegger, J. (2007). Cardiac C-Arm CT. In: Horsch, A., Deserno, T.M., Handels, H., Meinzer, HP., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2007. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-71091-2_45
Download citation
DOI: https://doi.org/10.1007/978-3-540-71091-2_45
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-71090-5
Online ISBN: 978-3-540-71091-2
eBook Packages: Computer Science and Engineering (German Language)