Patient Alignment Estimation in Six Degrees of Freedom Using a CT-scan and a Single X-ray Image

  • Conference paper
Bildverarbeitung für die Medizin 2008

Part of the book series: Informatik aktuell ((INFORMAT))

  • 1058 Accesses

Abstract

Particle beam treatment allows accurate dose delivery onto carcinogen tissue. The reachable accuracy is limited by patient alignment errors relative to the beam source. Errors can be corrected manually or by automatic comparison of two X-ray images to a CT-scan but correction mostly does not cover all degrees of freedom (DoF). In this contribution we present a solution that makes use of one X-ray image and computes full 6 DoF alignment correction by gray value based comparison to a CT. By using regions of interest, we are able to increase performance and reliability.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. Verhey LJ, Goitein M, McNulty P, et al. Precise positioning of patients for radiation therapy. Int J Radiat Oncol Biol Phys. 1982;8(2):289–94.

    Google Scholar 

  2. Thilmann C, Nill S, Tücking T, et al. Correction of patient positioning errors based on in-line cone beam CTs: Clinical implementation and first experiences. Int J Radiat Oncol Biol Phys. 2005;63(1):550–1.

    Google Scholar 

  3. Selby B, Sakas G, Walter S, et al. Detection of pose changes for spatial objects from projective images. In: Photogrammetric Image Analysis, The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences; 2007. p. 105–10.

    Google Scholar 

  4. Clippe S, Sarrut D, Malet C, et al. Patient setup error measurement using 3D intensity-based image registration techniques. Int J Radiat Oncol Biol Phys. 2003;56(1):259–65.

    Google Scholar 

  5. Press WH, Teukolsky SA, Vetterling WT, et al. Numerical Recipes in C. vol. 2. Cambridge: Cambridge University Press; 1992.

    MATH  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Selby, B.P., Sakas, G., Walter, S., Groch, W.D., Stilla, U. (2008). Patient Alignment Estimation in Six Degrees of Freedom Using a CT-scan and a Single X-ray Image. In: Tolxdorff, T., Braun, J., Deserno, T.M., Horsch, A., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2008. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-78640-5_26

Download citation

Publish with us

Policies and ethics