Abstract
We have developed a visualization environment to assist surgeons with therapy delivery inside the beating heart, in absence of direct vision. This system employs virtual reality techniques to integrate pre-operative anatomical models, real-time intra-operative imaging, and models of magnetically-tracked surgical tools. Visualization is enhanced via 3D dynamic cardiac models constructed from high-resolution pre-operative MR or CT data and registered within the intra-operative imaging environment. In this paper, we report our experience with a feature-based registration technique to fuse the pre- and intra-operative data during an in vivo intracardiac procedure on a porcine subject. Good alignment of the pre- and intra-operative anatomy within the virtual reality environment is ensured through the registration of easily identifiable landmarks. We present our initial experience in translating this work into the operating room and employing this system to guide typical intracardiac interventions. Given its extensive capabilities in providing surgical guidance in the absence of direct vision, our virtual environment is an ideal candidate for performing off-pump intracardiac interventions.
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
McVeigh, E.R., Guttman, M.A., Kellman, P., Raval, A.A., Lederman, R.J.: Real-time, interactive MRI for cardiovascular interventions. Acad Radiol 12, 1221–1227 (2005)
Lauritsch, G., Boese, J., Wigström, L., Kemeth, H., Fahrig, R.: Towards cardiac C-arm computed tomography. IEEE Trans. Med. Imaging 25, 922–934 (2006)
Linte, C.A., Wiles, A.D., Hill, N., Moore, J., Wedlake, C., Guiraudon, G.M., Jones, D.L., Bainbridge, D., Peters, T.M.: An augmented reality environment for image-guidance of off-pump mitral valve implantation. In: Medical Imaging 2007: Visualization and Image-Guided Procedures. Proc. of SPIE, vol. 6509 (2007) 65090N–12
Wiles, A.D., Guiraudon, G.M., Moore, J., Wedlake, C., Linte, C.A., Jones, D.L., Bainbridge, D., Peters, T.M.: Navigation accuracy for an intracardiac procedure using virtual reality-enhanced ultrasound. In: Medical Imaging 2007: Visualization and Image-Guided Procedures. Proc. of SPIE, vol. 6509 (2007) 61410W–10
Wierzbicki, M., Drangova, M., Guiraudon, G.M., Peters, T.M.: Validation of dynamic heart models obtained using non-linear registration for virtual reality training, planning, and guidance of minimally invasive cardiac surgeries. Med. Image Anal. 8, 387–401 (2004)
Wierzbicki, M., Peters, T.M.: Determining epicardial surface motion using elastic registration: Towards virtual reality guidance of minimally-invasive cardiac interventions. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2878, pp. 722–729. Springer, Heidelberg (2003)
Gobbi, D.G., Comeau, R.M., Peters, T.M.: Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift. In: Taylor, C., Colchester, A. (eds.) MICCAI 1999. LNCS, vol. 1679, pp. 920–927. Springer, Heidelberg (1999)
Linte, C.A., Wierzbicki, M., Moore, J., Guiraudon, G.M., Jones, D.L., Peters, T.M.: On enhancing planning and navigation of beating-heart mitral valve surgery using pre-operative cardiac models. In: Proc. of IEEE Eng. Med. Biol. Soc., pp. 475–478 (2007)
Guiraudon, G., Jones, D., Bainbridge, D., Peters, T.: Mitral valve implantation using off-pump closed beating intracardiac surgery: a feasability study. Interact Cardiovasc Thorac. Surg. 6, 603–607 (2007)
Zhang, Q., Eagleson, R., Peters, T.M.: Rapid voxel classification methodology for interactive 3d medical image visualization. In: Ayache, N., Ourselin, S., Maeder, A. (eds.) MICCAI 2007, Part II. LNCS, vol. 4792, pp. 86–93. Springer, Heidelberg (2007)
Vogt, S., Khamene, A., Niemann, H., Sauer, F.: An AR system with intuitive user interface for manipulation and visualization of 3D medical data. In: Proc. of Medicine Meets Virtual Reality. Stud. Health Technol. Inform., vol. 98, pp. 397–403 (2004)
Birkfellner, W., Figl, M., Matula, C., Hummel, J., Hanel, R., Imhof, H., Wanschitz, F., Wagner, A., Watzinger, F., Bergmann, H.: Computer-enhanced stereoscopic vision in a head-mounted operating binocular. Phys. Med. Biol. 48, 49–57 (2003)
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Peters, T.M., Linte, C.A., Moore, J., Bainbridge, D., Jones, D.L., Guiraudon, G.M. (2008). Towards a Medical Virtual Reality Environment for Minimally Invasive Cardiac Surgery. In: Dohi, T., Sakuma, I., Liao, H. (eds) Medical Imaging and Augmented Reality. MIAR 2008. Lecture Notes in Computer Science, vol 5128. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-79982-5_1
Download citation
DOI: https://doi.org/10.1007/978-3-540-79982-5_1
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-79981-8
Online ISBN: 978-3-540-79982-5
eBook Packages: Computer ScienceComputer Science (R0)