Abstract
Scattered photons degrade mammographic image quality, so, almost universally, a physical anti-scatter grid is used to limit their effect. Physical grids are not completely effective in rejecting only scattered photons, so patient dose must be increased in order to maintain low levels of quantum noise. The standard attenuation rate (SAR), a quantitative normalised representation of breast tissue for image analysis applications, incorporates a model of scatter, and a software correction of the image blurring arising from scatter within the image signal. A tissue equivalent phantom is used to investigate the possibility, in terms of both image sharpness and noise, of replacing the physical grid with the software correction in the SAR. Encouraging results are reported, software correction almost matching the performance of the grid, whilst maintaining a superior signal-to-noise ratio.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Tromans, C., Brady, M.: The Standard Attenuation Rate for Quantitative Mammography. In: Proceedings of 10th International Workshop on Digital Mammography (IWDM), Girona, Spain (2010)
Hubbell, J.H., Veigele, W.M.J., Briggs, E.A., Brown, R.T., Cromer, D.T., Howerton, R.J.: Atomic Form Factors, Incoherent Scattering Functions, and Photon Scattering Cross Sections. Journal of Physical and Chemical Reference Data 4, 471–538 (1975)
Hubbell, J.H., Overbo, I.: Relativistic atomic form factors and photon coherent scattering cross sections. Journal of Physical and Chemical Reference Data 8, 69–106 (1979)
Veldkamp, W.J., et al.: The value of scatter removal by a grid in full field digital mammography. Med. Phys. 30, 1712–1718 (2000)
Berger, M.J., Hubbell, J.H.: XCOM: Photon cross section on a personal computer, US Department of Commerce NBSIR 87-35971987
Tromans, C., et al.: Optimising Beam Quality Selection in Mammographic Acquisition using the Standard Attenuation Rate. In: Proceedings of 10th International Workshop on Digital Mammography (IWDM), Girona, Spain (2010)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Tromans, C.E., Diffey, J., Brady, S.M. (2010). Investigating the Replacement of the Physical Anti-scatter Grid with Digital Image Processing. In: MartÃ, J., Oliver, A., Freixenet, J., MartÃ, R. (eds) Digital Mammography. IWDM 2010. Lecture Notes in Computer Science, vol 6136. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13666-5_28
Download citation
DOI: https://doi.org/10.1007/978-3-642-13666-5_28
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-13665-8
Online ISBN: 978-3-642-13666-5
eBook Packages: Computer ScienceComputer Science (R0)